COMBI521
EN - 99
31. Press the
SAVE
key to partially save the test and to
end
the sequence of tests
. The instrument shows the
message contained in the following screen for a few
seconds.
Repeat the sequence again, if necessary.
STS
15/10 – 18:04
Sequence completed
A
STATUS
32.
Use the three selectors of the adapter and set the
following positions:
PP State
13A,20A,32A
or
63A
CP State
B
Fault
OK
Try and remove the connection plug of the adapter EV-
TEST100 in order to check whether the EVSE system
correctly blocks it
, as indicated in the screen on the
side.
Use the keys
,
to select the option “
OK
” in case of a
positive result, and press the
GO/STOP
key to carry on
with the test (see no. 34), or select the option “
NO OK
”
and press the
GO/STOP
key
to end the sequence of
tests
.
NOTE: some EVSE stations may not be provided with
the mechanical blocking system. In this case, select
the option “OK” to carry on with the tests.
STS
15/10 – 18:04
3/6 – Checking lock Status B
B L o c k
STATUS
OK
NO OK
33. Press the
SAVE
key to partially save the test and to
end
the sequence of tests
. The instrument shows the
message contained in the following screen for a few
seconds.
Repeat the sequence again, if necessary.
STS
15/10 – 18:04
Sequence completed
B Lock
STATUS