SOLAR300 - SOLAR300N
EN - 18
5.2.2. Single-MPPT
photovoltaic
system screen – Three-phase output
The instrument displays the following parameters:
DC
PV
AC
PARAMETERS CAPTION:
PRp:
Performance Ratio (ref. active powers)
Pdc
DC power at inverter input
DC
Photovoltaic panel performance
Vdc
DC voltage at inverter input
Idc
DC current at inverter input
Pac
AC power at inverter output
Pf
Three-phase power factor at inverter
output
AC
Three-phase inverter performance
Vac1,2,3
AC voltage at inverter output
Iac1,2,3
AC current at inverter output
Tpv
Default temperature of photovoltaic panels
Tenv
Default environmental temperature
The display of the Tenv or Tpv values in blue
indicates that the mentioned values are the
default ones, as the ones measured by SOLAR-
0x are not available (see § 5.3.2.4).
If the remote unit SOLAR-0x is connected to the
main, the following values are also available:
Irr
Solar irradiation
Pnom
Nominal power of the photovoltaic system
Tpv
Measured temperature of the photovoltaic
panels
Tenv
Measured environmental temperature
Fig. 20: Three-phase photovoltaic system page
5.2.3. Screen of photovoltaic systems with multi-MPPT inverter (only with MPP300)
For the sake of simplicity, further in this manual, the word “string” will be used, although
often the term “photovoltaic field” would be more correct. From the point of view of the
instrument, the management of a single string or of more parallel strings (photovoltaic
field) is identical.
The instrument SOLAR300N, used together with remote units SOLAR-02 and MPP300
(
optional
), allows testing PV systems characterized by inverters with 1 or more MPPTs
connected to the relevant PV fields (consisting in PV modules with the same direction and
inclination) and single-phase or three-phase output.
The remote unit MPP300 communicates with SOLAR300N (to manage data setting,
synchronization and download) through the USB connection cable and with the remote
unit SOLAR-02 (for recording irradiation and temperature values) via a wireless
radiofrequency (RF) connection, which is active up to a maximum distance of 1m between
the units.
For further details on the use of MPP300, please see the unit’s user manual.
Содержание SOLAR300
Страница 1: ...Copyright HT ITALIA 2017 Release EN 2 10 02 05 2017 SOLAR300 SOLAR300N User manual...
Страница 2: ......
Страница 159: ......