5.4.1.3. Items Start and Stop
This item determines the activation and deactivation mode of the recordings which can be
made with the instrument (see § 5.6).
For PV systems, the start mode is set to “Manual” (
Manu
) and cannot be changed:
Recording will therefore started/stopped only manually by pressing the
GO/STOP
key.
5.4.1.4. Item Integration period
This item allows setting the integration period (see § 10.11.1), that is to say the time
interval between two consecutive recordings in the whole measurement campaign. The
flag of this voice is always active and cannot be deselected.
1. Move the cursor on “
Integration period
” by means of the up or down arrow keys, so
that it is highlighted in blue.
2. Press the
F4
key (or the
MODIFY
item on the display). At the bottom of the display, the
instrument shows a control bar with the item “Integration period” highlighted.
3. Press the
F3
key (
MOD(+)
) or
F4
(
MOD(-)
) or the up or down arrow keys to set the
desired integration period, choosing between the following values:
1s, 5s, 10s, 30s,
1min, 2min, 5min, 10min, 15min, 30min, 60min
.
4. Press the
SAVE
or
ENTER
key (or the smart icon
) to save the setting made. The set
integration period is shown on the display.
5.4.1.5. Item General Parameters for use with SOLAR01 or SOLAR02 units
This item allows selecting the desired electrical mains parameters to be recorded. This
level includes different internal sub-levels, in which a detailed definition is possible,
according to the type of electric system (see § 5.3.1).
According to the selections made, the instrument displays the following informations:
Fig. 72: Section General Parameters: no selection
Fig. 98 shows the situation in which the instrument shows the “no parameter selected”
error, although it has highlighted item “General Parameters” on the display.
Note the writing on grey background and the unselected check box.
To exit, press the
F3
key (or the “
SEL
” item on the display).
In this case, a selection flag will appear next to item “General Parameters” and the
previous situation will change to the following screen with text on black ground and
selected check box: