SOLAR300 - SOLAR300N
EN - 97
5.7.2.2. Result for data of RecPV type
This page (not available for RecPV* data as these recordings are, in fact, incomplete)
displays the values of the parameters measured and calculated during the testing /
recording phase. In particular, the instrument:
Do not show any results if do not exist on the PV installation a
“stable irradiance
”
condition more than the minimum irradiance threshold (see § 5.3.3.3)
Display the best performance values if during the recording, the Irradiance values
reached the “
stable
” condition and its values were higher than the minimum irradiance
threshold (see § 5.3.3.3)
CAUTION
The instrument acknowledge the “
stable irradiance
” condition for a detected
point of measure when, with MEDIUM value of irradiance measured by the
pyranometer > set minimum irradiance threshold (see § 5.3.3.3),
the
difference between Maximum and Minimum values of irradiance in the
same point is < 20W/m
2
(with IP
1min)
If more points satified the a.m. conditions, the meter consider the point
correspondent to a maximum efficiencies combination
The instrument displays the following parameters:
DC
FV
AC
Legend of parameters for single-phase PV systems:
PRp
Performance Ratio (active power)
Pdc
DC power at inverter input
DC
Photovoltaic panel performance
Vdc
DC voltage at inverter input
Idc
DC current at inverter input
Pac
AC power at inverter output
Pf
Power factor at inverter output
AC
Inverter performance
Vac
AC voltage at inverter output
Iac
AC current at inverter output
Irr
Solar irradiation
Pnom
Nominal power of the photovoltaic system
Tpv
Temperature of photovoltaic panels
Tenv
Environmental temperature
The display of the Tenv or Tpv values in blue
indicates that the mentioned values are the
default ones, as the ones measured by SOLAR-
0x are not available (see § 5.3.2.4
).
Fig. 136: Page of a PV-1 system
Содержание SOLAR300
Страница 1: ...Copyright HT ITALIA 2017 Release EN 2 10 02 05 2017 SOLAR300 SOLAR300N User manual...
Страница 2: ......
Страница 159: ......