SOLAR300 - SOLAR300N
EN - 52
5.4.1.9. Item General Parameters for use with MPP300 unit
After setting MPP300 as remote unit (see § 5.3.3) the instrument will display a selection
tree, in which it will be possible to change only the “comment” fields and the value of the
integration period.
Fig. 78: Section of General Parameters: no selection
The list of the recorded quantities cannot be changed and is only related to the number of
DC inputs set (MPPT) and to the type of electric system at the inverter output (single-
phase or three-phase).
PV systems with MPP300
GENERAL MENU SECTION
PARAMETER
SETTING
Recording configuration
Comments (empty)
Start Manu
Stop Manu
Integration period
5 sec .. 60min
General Parameters
MPP300-1
system
VDCx, IDCx, PDCx,
Hz, V1N, I1, P1, Ea1
MPP300-3
system
VDCx, IDCx, PDCx,PDCtot
Hz, V1N,V2N,V3N,V12,V23,V31,
I1, I2, I3, P1, P2, P3,Ptot, Ea1,
Ea2, Ea2, Eatot
SOLAR-02
Irradiation, Celle Temperature, Environmental
Temperature
x = 1,2,3 according to the number of DC inputs (MPPT) set.
Press the
SAVE
or
ENTER
keys (or the smart icon
) to save each selected setting. In
this condition, the instrument shows a window to confirm the saving. In this window,
confirm by pressing “Ok”. Once the operation has been completed, the instrument goes
back to the general menu screen.
To quit the modifications made or to exit without saving, press the
ESC
key (or the smart
icon ).