Diagnostics
57
Edge Switch 2/12 Service Manual
10
An event code 426 (SDRAM problem), 810 (high-temperature warning), or 811
(critically-hot temperature warning) indicates an intermittent problem that may
result in switch failure.
Is the appearance of this event code a recurring problem?
NO
YES
↓
A CTP card failure is indicated. Replace the switch.
Exit MAP.
Perform the data collection procedure and contact the next level of support. Refer
to
Collect Maintenance Data” on page 105
11
An event code 433 or 440 indicates a CTP card failure. Replace the switch. Exit
MAP.
12
Does the EWS interface appear operational?
NO
YES
↓
Go to
step 14
.
13
A
Page cannot be found
,
Unable to locate the server
,
HTTP
404 - file not found
, or other similar message appears. The message
indicates the PC cannot communicate with the switch because:
■
The switch-to-PC Ethernet link could not be established.
■
AC power distribution in the switch failed, or AC power was disconnected.
■
The switch CTP card failed.
The EWS interface is not operational and fault isolation must be performed at the
switch. Go to
step 4
.