Event Codes
149
Edge Switch 2/12 Service Manual
Table 39: Event Code 150
Message:
Zone merge failure.
Severity:
Informational.
Explanation:
During ISL initialization, the zone merge process failed. Either an incompatible zone
set was detected or a problem occurred during delivery of a zone merge frame. This
event code always precedes a 070 ISL segmentation event code, and represents the
reply of an adjacent fabric element in response to a zone merge frame. Refer to the
event data for the failure reason.
Action:
Action depends on the failure reason specified in the event data.
Event Data:
Bytes 0–3 of the event data specify affected E_Port number(s). Bytes 8–11 specify the
failure reason as follows:
01 = Invalid data length–An invalid data length condition caused an error in a zone
merge frame. Disconnect the E_Port link, then reconnect the link. If the condition
persists, perform the procedure described in “
08 = Invalid zone set format–An invalid zone set format caused an error in a zone
merge frame. Disconnect the E_Port link, then reconnect the link. If the condition
persists, perform the procedure described in “
09 = Invalid data–Invalid data caused a zone merge failure. Inspect bytes 12–15 of
the event data for error codes. Refer to error code definitions listed on the following
page to correct the problem.
0A = Cannot merge–A
Cannot Merge
condition caused a zone merge failure.
Inspect bytes 12–15 of the event data for error codes. Refer to error code definitions
listed on the following page to correct the problem.
F0 = Retry limit reached–A retry limit reached condition caused an error in a zone
merge frame. Disconnect the E_Port link, then reconnect the link. If the condition
persists, perform the procedure described in “
F1 = Invalid response length–An invalid response length condition caused an error in
a zone merge frame. Disconnect the E_Port link, then reconnect the link. If the
condition persists, perform the procedure described in “
F2 = Invalid response code–An invalid response code caused an error in a zone
merge frame. Disconnect the E_Port link, then reconnect the link. If the condition
persists, perform the procedure described in “
Содержание StorageWorks Edge Switch 2/12
Страница 16: ...About this Guide 16 Edge Switch 2 12 Service Manual ...
Страница 124: ...Repair Information 124 Edge Switch 2 12 Service Manual ...
Страница 132: ...Illustrated Parts Breakdown 132 Edge Switch 2 12 Service Manual ...
Страница 172: ...Event Codes 172 Edge Switch 2 12 Service Manual ...