Diagnostics
40
Edge Switch 2/12 Service Manual
19
At the switch, is the green PWR LED at the switch front bezel illuminated?
NO
YES
↓
Go to
step 24
.
20
Is the switch connected to facility AC power?
NO
YES
↓
Go to
step 23
.
21
Connect the switch to facility AC power. Inspect the switch for indications of
being powered on, such as:
■
At the front bezel, an illuminated PWR LED (green) or ERR LED (amber).
■
Illuminated LEDs adjacent to Fibre Channel ports.
■
Audio emanations and airflow from cooling fans.
Does the switch appear powered on?
YES
NO
↓
A power distribution problem is indicated. Go to
step 18
to obtain
event codes. If no event codes are found, go to “
” on page 43. Exit MAP.
22
Is the green PWR LED at the switch front bezel illuminated?
NO
YES
↓
Go to
step 24
.
A faulty PWR LED is indicated, but switch and Fibre Channel port operation is
not disrupted. The LED is connected to CTP card circuitry, and if this problem is
a concern to the customer, the switch must be replaced. Exit MAP.