Diagnostics
76
Edge Switch 2/12 Service Manual
40
Does the customer desire a device connection?
YES
NO
↓
The switch appears operational and the No Light state is acceptable
to the customer. No action is required. Exit MAP.
41
Connect a Fibre Channel device to the port as directed by the customer.
Did connection of a device to the port solve the problem?
NO
YES
↓
The switch appears operational. Exit MAP.
42
A problem exists with the fiber-optic cable, attached device, or SFP optical
transceiver. Go to
step 17
.
MAP 0600: Fabric, ISL, and Segmented Port Problem Determination
This MAP describes fault isolation of fabric logout, interswitch link (ISL), and
E_Port segmentation problems. Failure indicators include:
■
An event code recorded at the EWS Event Log.
■
A segmentation reason associated with a Fibre Channel port at the EWS
interface.
1
Base product Fibre Channel ports on the Edge Switch 2/12 can be configured only
as F_Ports or fabric loop (Fx_Ports). Installation of the optional E_Port (or Full
Fabric) feature key is required to configure ports as E_Ports and enable ISL
connections to other fabric elements.
Is the E_Port (or Full Fabric) feature key installed on the switch?
NO
YES
↓
Go to
step 3
.