Diagnostics
58
Edge Switch 2/12 Service Manual
14
Inspect the power supply (includes fan modules) operational state at the EWS
interface.
1. At the View panel, click the FRU Properties tab. The FRU Properties tab
displays.
2. Inspect the Status field for the power supply.
Does the Status field display a
Failed
message for the power supply?
NO
YES
↓
A fan module or power supply failure is indicated. Replace the
switch. Exit MAP.
15
Inspect the CTP card operational state at the EWS interface.
1. At the View panel, click the FRU Properties tab. The FRU Properties tab
displays.
2. Inspect the Status field for the CTP card.
Does the Status field display a
Failed
message for the CTP card?
NO
YES
↓
A CTP card failure is indicated. Replace the switch. Exit MAP.
Additional analysis is not described in this MAP. Go to “
on page 32. If this is the second time at this step, contact the next level of support.
Exit MAP.