Diagnostics
67
Edge Switch 2/12 Service Manual
21
The attached device is causing the recurrent link incident or No Light message.
Notify the customer of the problem and have the system administrator:
1. Inspect and verify operation of the attached device.
2. Repair the attached device if a failure is indicated.
3. Monitor port operation for approximately five minutes.
Did a link incident or No Light message recur?
YES
NO
↓
The attached device, Fibre Channel link, and switch appear
operational. Exit MAP.
Contact the next level of support. Exit MAP.
22
The switch port reporting the problem is causing the recurrent link incident or No
Light message. The recurring problem indicates port degradation and a possible
pending failure. Go to
step 21
.
23
As indicated by a message or event code 081, a port has an invalid attachment.
The information in the Port Properties dialog box specifies the reason, as listed
in
Table 10: Invalid Attachment Reasons and Actions
Reason
Action
Unknown
Contact the next level of support.
ISL connection not allowed.
Go to
step 24
.
Incompatible switch.
Go to
step 25
.
External loopback plug connected.
Go to
step 26
.
N-Port connection not allowed.
Go to
step 24
.
Non-HP M-series switch at other end.
Go to
step 25
.
Unauthorized port binding WWN.
Go to
step 12
.
Unresponsive node.
Go to
step 28
.
Fabric binding mismatch.
Go to
step 31
.
Содержание StorageWorks Edge Switch 2/12
Страница 16: ...About this Guide 16 Edge Switch 2 12 Service Manual ...
Страница 124: ...Repair Information 124 Edge Switch 2 12 Service Manual ...
Страница 132: ...Illustrated Parts Breakdown 132 Edge Switch 2 12 Service Manual ...