Event Codes
164
Edge Switch 2/12 Service Manual
Distribution:
Switch
HAFM Appliance
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
✔
Table 61: Event Code 508 (Continued)
Table 62: Event Code 510
Message:
SFP optical transceiver hot-insertion initiated.
Severity:
Informational.
Explanation:
Installation of a small form factor pluggable (SFP) optical transceiver was initiated
with the switch powered on and operational. The event indicates that operational
firmware detected the presence of the transceiver.
Action:
No action required.
Event Data:
Byte
0
= port number (
00
through
11
).
Bytes
4
through
7
= elapsed millisecond tick count.
Distribution:
Switch
HAFM Appliance
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
Table 63: Event Code 512
Message:
SFP optical transceiver nonfatal error.
Severity:
Minor.
Explanation:
Switch firmware detected an SFP optical transceiver non-fatal error.
Action:
Replace the failed transceiver with a functional transceiver of the same type.
Event Data:
Byte
0
= port number (
00
through
11
).
Byte
1
= engineering reason code.
Bytes
4
through
7
= elapsed millisecond tick count.
Distribution:
Switch
HAFM Appliance
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
Содержание StorageWorks Edge Switch 2/12
Страница 16: ...About this Guide 16 Edge Switch 2 12 Service Manual ...
Страница 124: ...Repair Information 124 Edge Switch 2 12 Service Manual ...
Страница 132: ...Illustrated Parts Breakdown 132 Edge Switch 2 12 Service Manual ...