Event Codes
167
Edge Switch 2/12 Service Manual
Table 68: Event Code 525
Message:
FL_Port arbitration timeout.
Severity:
Informational.
Explanation:
A switch port could not win loop arbitration within the specified loop protocol time
out value (LP_TOV).
Action:
Switch firmware reinitializes the arbitrated loop. No user action required.
Event Data:
Byte
0
= port number (
00
through
11
).
Distribution:
Switch
HAFM Appliance
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
Table 69: Event Code 581
Message:
Implicit incident.
Severity:
Major.
Explanation:
The event caused an implicit Fibre Channel link incident.
Action:
A link incident record (LIR) is generated and sent to the attached server using the
reporting procedure defined in T11/99-017v0 (OSI). If fault isolation at the server
does not detect a failure, the problem may be due to a port failure. Go to “
” on page 32 to perform fault isolation.
Event Data:
Refer to the T11/99-017v0 document for the specific link incident record format.
Distribution:
Switch
HAFM Appliance
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔