Diagnostics
87
Edge Switch 2/12 Service Manual
■
Increase the ISL link speed between the switches reporting the problem (from
1 Gbps to 2 Gbps).
■
Reroute Fibre Channel traffic by moving device connections to a
less-congested region of the fabric.
Did the corrective action solve the problem and relieve the reported low
BB_Credit condition?
NO
YES
↓
The ISL appears operational. Exit MAP.
Contact the next level of support. Exit MAP.
23
A 150 event code indicates a zone merge process failed during ISL initialization.
Either an incompatible zone set was detected or a problem occurred during
delivery of a zone merge frame. This event code always precedes a 070 event
code, and represents the reply of an adjacent fabric element in response to a zone
merge frame.
Obtain supplementary event data for each 150 event code.
1. At the EWS Event Log, examine the first 12 bytes (0 through 11) of event
data.
2. Bytes 0 through 3 specify the E_Port number (00 through 11) reporting the
problem. Bytes 8 through 11 specify the failure reason, as specified in
Table 14: Bytes 8 through 11 Failure Reasons and Actions
Bytes 8 - 11
Failure Reason
Action
01
Invalid data length.
Go to
step 24
.
08
Invalid zone set format.
Go to
step 24
.
09
Invalid data.
Go to
step 25
.
0A
Cannot merge.
Go to
step 25
.
F0
Retry limit reached.
Go to
step 24
.
F1
Invalid response length.
Go to
step 24
.
F2
Invalid response code.
Go to
step 24
.
Содержание StorageWorks Edge Switch 2/12
Страница 16: ...About this Guide 16 Edge Switch 2 12 Service Manual ...
Страница 124: ...Repair Information 124 Edge Switch 2 12 Service Manual ...
Страница 132: ...Illustrated Parts Breakdown 132 Edge Switch 2 12 Service Manual ...
Страница 172: ...Event Codes 172 Edge Switch 2 12 Service Manual ...