Diagnostics
56
Edge Switch 2/12 Service Manual
6
Visual inspection or an event code 300, 301, or 302 indicates one or more cooling
fans failed. Replace the switch. Exit MAP.
7
Inspect the switch front panel.
Is the green PWR LED illuminated and the amber ERR LED illuminated and
blinking (beaconing)?
YES
NO
↓
Go to
step 9
.
8
Unit beaconing is enabled for the switch.
1. Consult the customer and next level of support to determine the reason unit
beaconing is enabled.
2. Disable unit beaconing at the EWS interface.
a.
At the View panel, select Operations at the left side of the panel. The
Operations panel opens with the Switch and Beacon pages displayed.
b.
Click Deactivate to disable beaconing. The message
Your changes
have been successfully activated
appears.
Was unit beaconing enabled because a failure or degradation was suspected?
NO
YES
↓
Go to
step 1
.
The switch appears operational. Exit MAP.
9
Is the green PWR LED illuminated, the amber ERR LED illuminated, and all
Fibre Channel traffic disrupted (not operational)?
NO
YES
↓
A CTP card failure is indicated. Replace the switch. Exit MAP.
Analysis for this failure is not described in this MAP. Go to “
” on page 32. If this is the second time at this step, contact the next level of
support. Exit MAP.