
This section describes how to configure host ports on Fibre Channel (FC) or iSCSI
controller modules. No host-port configuration is needed for SAS controller
modules.
On the Host Port Configuration page you can view the location, link speed, and
topology of each FC host port in each controller module.
This page shows the following information:
Port number and location – The shaded box represents the physical position of
the port on the controller module. For each port, the upper bar represents the host
ports on controller module A and the lower bar represents host ports on controller
module B.
Link Speed – 2 GBit/Second or 4 GBit/Second. A host port's link speed must
match the speed of the HBA or switch to which the port is connected.
Topology – Either Loop or Point to Point. “Not Available IOM Down” appears if
the controller is down and topology information is unavailable.
On this page you can set FC host port link speeds. From the Advanced Options
panel you can view and set the following:
FC host port loop ID
FC host port interconnect status (dual-controller system only)
FC host port topology
Содержание StorageWorks 2000 Series
Страница 16: ......
Страница 28: ......
Страница 108: ......
Страница 122: ......
Страница 134: ......
Страница 148: ......
Страница 180: ......
Страница 194: ......
Страница 226: ......
Страница 243: ......
Страница 244: ......
Страница 246: ......
Страница 254: ......
Страница 259: ...The following figure shows how port WWNs and mapped volumes are presented if controller B fails ...
Страница 264: ...The following figure shows how port IP addresses and mapped volumes are presented if controller B fails ...
Страница 318: ......
Страница 330: ......