
73
Informational
(Active-active environment)
The two controllers are
communicating with each other and
cache redundancy is enabled.
74
Informational
The FC loop ID for the specified
vdisk was changed to be consistent
with the IDs of other vdisks. This can
occur when drives containing a vdisk
are inserted from an enclosure having
a different FC loop ID.
This event is also logged by the new
owning controller after virtual disk
ownership is changed.
75
Informational
The specified volume’s LUN has
been unassigned because it conflicts
with LUNs assigned to other
volumes. This can happen when disk
drives containing data for a mapped
volume have been inserted from
another enclosure.
If you want hosts to access the
volume data on the inserted drives,
map the volume with a different
LUN.
76
Informational
The controller is using default
configuration settings. This event
occurs on the first power up, and
might occur after a firmware update.
If you have just performed a
firmware update and your system
requires special configuration
settings, you must make those
configuration changes before your
system will operate as before.
77
Informational
The cache was initialized as a result
of power up or failover.
78
Warning
The controller could not use an
assigned spare for a vdisk because the
spare’s capacity is too small. This
occurs when a vdisk’s status becomes
critical and all global spares are too
small or (if dynamic spares are
enabled) all disk drives are too small.
Replace existing spares or add
spares with enough capacity to
replace the smallest drive in the
vdisk. The vdisk size is limited by
its drive with the least capacity.
79
Informational
The trust vdisk operation has
completed successfully.
Содержание StorageWorks 2000 Series
Страница 16: ......
Страница 28: ......
Страница 108: ......
Страница 122: ......
Страница 134: ......
Страница 148: ......
Страница 180: ......
Страница 194: ......
Страница 226: ......
Страница 243: ......
Страница 244: ......
Страница 246: ......
Страница 254: ......
Страница 259: ...The following figure shows how port WWNs and mapped volumes are presented if controller B fails ...
Страница 264: ...The following figure shows how port IP addresses and mapped volumes are presented if controller B fails ...
Страница 318: ......
Страница 330: ......