Recovering corrupted MSA controller
fi
rmware
If the controller detects a
fi
rmware corruption, the following message is displayed on the LCD panel:
ERROR: ROM CORRUPT
SEND IMG VIA XMODEM
To recover the controller, you must obtain a current
fi
rmware image and send it to the controller using a
serial connection.
1.
Go to the MSA1510i support website and obtain the latest controller
fi
rmware.
NOTE:
If you are not yet registered, select the option to receive e-mail noti
fi
cations, advisories, and
support alerts about MSA system hardware,
fi
rmware, drivers, and software components.
This alert noti
fi
cation system is a one-way broadcasting method used to distribute important
notices about HP products. Information about your MSA is not requested when subscribing
to this service.
2.
Establish a serial connection to the affected controller:
• Use the custom CLI con
fi
guration cable shipped with the MSA.
• Use a terminal emulator program that supports the Xmodem protocol, such as HyperTerminal.
• Use the following emulator connection settings:
• Bits per second: 19200
• Data bits: 8
• Parity: None
• Stop bits: 1
• Flow control: None
A blank emulator window is displayed—no CLI prompt is displayed.
1510i Modular Smart Array installation and user guide
91