Message
Type
Description
Action
44 REDUNDANCY
FAILED MISMATCH
HARDWARE
Error
Both array controllers must contain
the same hardware for them to
successfully enter redundant mode.
The current array controllers do
not contain the same hardware,
possibly because one has an
attached Fibre Channel daughter
card and the other does not.
If the MSA is currently involved
in host I/O, remove the
standby
array controller, add or replace
the Fibre Channel daughter card
as needed, wait 10 seconds, and
then reinsert it, ensuring that it is
fully seated in the chassis.
If this does not resolve the issue,
wait until downtime is available.
Power off the MSA, remove both
array controllers, add or remove
Fibre Channel daughter cards as
needed on both, and reinsert them,
ensuring they are fully seated in
the chassis.
Should the issue persist, contact
HP support.
45 REDUNDANCY
FAILED MISMATCH
FIRMWARE
Error
Both array controllers must be
running the same version of
fi
rmware for them to successfully
enter redundant mode. A process
called
fi
rmware cloning, which
attempts to make them both the
same
fi
rmware level, has failed.
Manually update the
fi
rmware on
the older array controller.
46 REDUNDANCY
HALTED EXPAND
ACTIVE
Informational
If volume expansion is in progress
then redundancy is not supported.
Volume expansion is initiated
and tracked using the Array
Con
fi
guration Utility (ACU) or
Storage Management Utility
(SMU). After the volume expansion
is complete, redundancy is
automatically re-established.
47 REDUNDANCY
FAILED CACHE SIZE
MISMATCH
Error
Both array controllers must have
the same size of cache memory to
successfully enter redundant mode.
If the MSA is currently involved
in host I/O, remove the
standby
array controller, add or remove
cache memory as needed, wait
10 seconds, and then reinsert it,
ensuring that it is fully seated in
the chassis.
If this does not resolve the issue,
wait until downtime is available.
Power off the MSA, remove both
array controllers, add or remove
cache memory as needed on both,
and reinsert them, ensuring they
are fully seated in the chassis.
Should the issue persist, contact
HP support.
48 REDUNDANCY
HALTED FIRMWARE
CLONED
Informational
Both array controllers must run the
same version of
fi
rmware for them
to successfully enter redundant
mode. A process called
fi
rmware
cloning has been successfully
completed in order to make them
both the same
fi
rmware level. The
standby
array controller is restarted
automatically so they can attempt
to achieve redundancy again.
112
MSA controller LCD panel message descriptions