Message
Type
Description
Action
108 VOLUME #<n>
STATE MISSING
DRIVES
Error
The con
fi
gured volume is missing
too many of the SCSI hard drives
that it is composed of, making it
unusable. The volume is disabled.
Power off the MSA and then
all attached storage enclosures.
Unplug and reinsert all SCSI hard
drives ensuring they are fully
seated in their bays. Check the
cables connecting the MSA to
any attached storage enclosures.
Power on the attached enclosures
and then the MSA.
109 VOLUME #<n>
STATE WRONG DRIVE
REPLACED
Error
The con
fi
gured volume appears
to have had known, good SCSI
drives replaced instead of known,
failed drives.
Power off the MSA. Restore the
good drives and replace the failed
drives.
110 VOLUME #<n>
EXPANSION DISABLED
Informational
The volume expansion operation
on the con
fi
gured volume has been
disabled. This may be because
a rebuild operation is ongoing,
another expansion is already
running, or the cache memory is
disabled due to a low battery.
The expansion will start after the
condition has been cleared.
111 VOLUME #<n>
INITIALIZING
PARITY
Informational
The array controller is calculating
and storing parity information
for the con
fi
gured volume and
therefore performance may be
lower until it completes.
112 VOLUME #<n>
REBUILD FAILURE
Error
The rebuild operation on the
con
fi
gured volume has failed.
If the volume is still operating in
regenerative mode, remove the
new SCSI drive that was added
as a replacement for the original
failed drive and replace it with a
different new drive.
113 VOLUME #<n>
EXPANSION FAILURE
Error
The volume expansion operation
on the con
fi
gured volume has
failed.
Open the HP Storage Management
Utility or MSA-CLI and use it to
determine the state of the volume.
If the volume is still operational,
then it is possible to retry the
operation.
114 VOLUME #<n>
STATE DELETED
Informational
The con
fi
gured volume has been
deleted and is no longer available.
Volumes are deleted by using the
HP Storage Management Utility or
MSA-CLI.
115 VOLUME #<n>
MEDIA EXCHANGED
Informational
All failed hard drives of the
speci
fi
ed volume have been
replaced by good hard drives
or all unplugged hard drives in
the volume have been plugged
back in. This message should be
followed by message
02 ENABLE
VOLUME <n>?
'<'=NO,
'>'=YES
.
See the entry for
02 ENABLE
VOLUME <n>?
'<'=NO,
'>'=YES
.
120 CONFIGURED
VOLUMES <n>
Informational
The speci
fi
ed number of con
fi
gured
volumes were detected at power
up.
1510i Modular Smart Array installation and user guide
119
Содержание StorageWorks 1510i - Modular Smart Array
Страница 8: ...8 ...
Страница 58: ...58 Installation ...
Страница 76: ...76 Configuration ...
Страница 104: ...104 Operation and management ...
Страница 140: ...140 Regulatory compliance and safety ...
Страница 152: ...152 MSA1510i worksheets ...