13.
View the messages displayed on the array controller LCD panel during startup to con
fi
rm that the
fi
rmware was installed successfully and that the array controller restarts successfully.
NOTE:
In dual-controller con
fi
gurations,
fi
rmware on the two controllers is compared each time
the MSA chassis is restarted. If the versions are mismatched, the system prompts to clone
the
fi
rmware on the controller with the latest version over to the controller with the earlier
version
fi
rmware. (For the system to operate in a dual-controller mode,
fi
rmware on the
controllers must match.)
The following message is displayed on the LCD panel of the controller with the earlier
fi
rmware:
07 CLONE FIRMWARE ? ‘<‘ = NO, ‘>’ = YES
Press the > button on the LCD panel to clone the
fi
rmware. During the cloning process,
informational messages are displayed on the controller LCD panels. When the cloning
process is complete, the just-updated controller automatically restarts.
Cloning controller
fi
rmware
NOTE:
Cloning is possible only in dual-controller con
fi
gurations.
Each time a system with two controllers is powered on or restarted, or if a second controller is hot
plugged into a single-controller con
fi
guration, the
fi
rmware versions on the controllers are compared. If
the
fi
rmware versions on the two controllers differ, the array controller LCD panel prompts to clone the
fi
rmware from one controller to the other controller, so that they have the same version.
The determination as to which
fi
rmware version is used is based on the following criteria:
•
If the MSA is being powered up or restarted with both controllers installed, the most recent version
of
fi
rmware is used, regardless of which controller it resides on.
•
If the MSA is already operating and an optional controller is hot plugged, then the version of
fi
rmware
that is on the original (non-hot plugged) controller is used, regardless of its version. This ensures that
any host-initiated I/O to the controller is not interrupted.
If the
fi
rmware version on the two controllers is not the same, the following prompt is displayed in the
controller LCD panel:
CLONE FIRMWARE ? ‘<‘ = NO, ‘>' = YES
If
>
is pressed or a response is not made to the prompt within 60 seconds, the following messages are
displayed on the LCD panel while
fi
rmware is copied from the active controller to the standby controller
and the standby controller is automatically restarted:
ROM CLONING STARTED
ARRAY CONTROLLER RESTARTING
STARTUP COMPLETE
The two controllers should now operate in redundant mode.
88