Message
Type
Description
Action
18 ONLINE UPGRADE
INCOMPLETE
Error
An online
fi
rmware update was
successful, but a subsequent
step failed. In dual-controller
con
fi
gurations, this may cause the
other to not update properly.
Restart the system.
In dual-controller con
fi
gurations,
if the
07 CLONE FIRMWARE?
'<'=NO, '>'=YES
message is
displayed, select >.
19 ONLINE UPGRADE
REDUNDANCY HALTED
Informational
In dual-controller con
fi
gurations,
each controller restarts at least
once during an online
fi
rmware
update. During these restarts, the
system is not redundant.
20 INITIALIZING
SCSI SUBSYSTEM
Informational
The SCSI subsystem is being
initialized as part of the power-on
sequence.
21 SCANNING FOR
SCSI DEVICES
Informational
The MSA is scanning for attached
SCSI devices as part of the
power-on sequence.
22 INITIALIZING
SCSI DEVICES
Informational
The MSA is initializing all
discovered SCSI devices as part of
the power-on sequence.
23 SCSI SUBSYSTEM
HARDWARE FAILURE
Error
The SCSI subsystem has
experienced a hardware failure
and is not operating correctly. The
array controller has halted itself
and cannot continue.
Contact HP support.
24 BAD SCSI BUS
MODE NON-LVD
DEVICE FOUND
Error
The MSA does not support SCSI
Single Ended (SE) devices; it
only supports SCSI Low Voltage
Differential (LVD) devices.
Power off the MSA and then
examine all attached SCSI devices.
Remove any SE devices and
replace them with LVD devices.
25 FW VERSION IS
NOT SUPPORTED
Error
The array controller has been
inserted in an MSA chassis in
which it is not supported.
Contact HP support.
26 BAD SCSI TARGET
Error
The MSA is not properly identifying
an external storage enclosure.
Do the following:
1.
Remove power from the MSA
and all attached storage
enclosures.
2.
Reseat all cables to the
external storage enclosures.
3.
Verify that all cables are
connected in a supported
manner.
4.
Apply power to the external
storage enclosures.
5.
Apply power to the MSA.
Should the issue persist, contact
HP support.
30 I2C READ
FAILURE <I2C
device name>
Error
The MSA has a number of internal
devices that are accessed via an
I2C hardware bus. One of these
devices failed when attempting to
read from it. Certain I2C devices
are considered critical and will
result in a failure of the array
controller, while others may result
in some loss of functionality (such
as lost display messages).
If the issue persists, contact HP
support.
110
MSA controller LCD panel message descriptions
Содержание StorageWorks 1510i - Modular Smart Array
Страница 8: ...8 ...
Страница 58: ...58 Installation ...
Страница 76: ...76 Configuration ...
Страница 104: ...104 Operation and management ...
Страница 140: ...140 Regulatory compliance and safety ...
Страница 152: ...152 MSA1510i worksheets ...