Message
Type
Description
Action
02 ENABLE VOLUME
<n>?
‘<'=NO,
‘>'=YES
User input
An issue has been found with a
con
fi
gured volume that may result
in data loss, so the volume has
been disabled. The exact nature of
the issue is detailed in a previous
LCD display message.
Yes
= the volume is enabled
(regardless of the issue). The
volume attempts to return to its
normal operating state and the
data is accessible.
No
(or no input) = the volume
remains disabled. The volume
stays in the failed state and the
data is not accessible. During this
time, the user can attempt to
fi
x
the issue.
03 CRITICAL
LOCK-UP DETECTED.
CODE=<n>h
Error
A critical error has been detected
by the array controller
fi
rmware.
To prevent any possible data loss,
the
fi
rmware has entered a lock-up
state. The provided code contains
engineering speci
fi
c information
about the lock-up condition.
In dual-controller con
fi
gurations
where only one controller is
locked-up, remove the array
controller in question, wait 10
seconds, and then reinsert it,
ensuring that it is fully seated in
the chassis.
In single-controller con
fi
gurations
and in dual-controller
con
fi
gurations where both
controllers are locked-up, restart
the MSA chassis.
If the issue persists, contact HP
support.
04 ENABLE VOLUMES
? ‘<'=NO, ‘>'=YES
User input
An issue has been found with all
of the con
fi
gured volumes that
may result in data loss. The exact
nature of the issue is detailed in a
previous display message.
Yes
= the volume is enabled
(regardless of the issue). The
volume attempts to return to its
normal operating state and the
data is accessible.
No (or no input)
= the volume
remains disabled. The volume
stays in the failed state and the
data is not be accessible. During
this time, the user can attempt to
fi
x the issue.
05 SYSTEM NAME:
<name>
Informational
The user-assigned name for the
MSA system. This name can
be assigned using the Storage
Management Utility (SCU) or the
MSA Command Line Interface
(MSA-CLI).
06 RESTARTING
SYSTEM
Informational
The system is being restarted.
108
MSA controller LCD panel message descriptions
Содержание StorageWorks 1510i - Modular Smart Array
Страница 8: ...8 ...
Страница 58: ...58 Installation ...
Страница 76: ...76 Configuration ...
Страница 104: ...104 Operation and management ...
Страница 140: ...140 Regulatory compliance and safety ...
Страница 152: ...152 MSA1510i worksheets ...