Item 1
Activity LED
nl
Item 2
Online LED
nl
Item 3 Fault
LED
nl
Meaning
On
Off
Off
The hard drive is being accessed in
one
of the following ways:
•
The hard drive is not con
fi
gured as part of an array.
•
The hard drive is a replacement and rebuild has not yet started.
•
The hard drive is spinning up during POST.
Do not remove the hard drive. Removing a hard drive at this time could
terminate the current operation and cause data loss.
Blinking
Blinking
Blinking
The hard drive is being accessed in
one
of the following ways:
•
The hard drive has been selected for identi
fi
cation in HP-SIM,
MSA-CLI, or other supported management utility.
•
The hard drive is being upgraded.
Do not remove the hard drive. Removing a hard drive at this time can
cause data loss in non-fault-tolerant con
fi
gurations.
Off
Off
Off
The hard drive is not being accessed and is not con
fi
gured as part of an
array. If necessary, it is safe to replace the hard drive. This hard drive
is in
one
of the following states:
•
The hard drive is not con
fi
gured as part of an array.
•
The hard drive is con
fi
gured as an online spare.
On or off
Blinking
Off
The hard drive is being accessed in
one
of the following ways:
•
The hard drive is a replacement hard drive and is being rebuilt.
•
If the online LEDs of all of the other hard drives in the array are
blinking, an expansion is occurring.
Do not remove the hard drive. Removing a hard drive at this time can
cause data loss.
Off
Off
On
The hard drive has failed and has been placed of
fl
ine. It is safe to
replace the hard drive.
Off, on, or
blinking
On
Off
The hard drive is online and con
fi
gured as part of an array, If necessary,
and if all other hard drives in the same array are online and working, it
is safe to replace the hard drive.
one
of the following is happening:
•
If the Activity LED is off, the drive is con
fi
gured and online but not
currently active.
•
If the Activity LED is on or blinking, the drive is con
fi
gured, online,
and currently active.
Off, on, or
blinking
On or off
Blinking
A predictive failure alert has been received for this drive. Replace the
hard drive as soon as possible.
24
System components and LEDs
Содержание StorageWorks 1510i - Modular Smart Array
Страница 8: ...8 ...
Страница 58: ...58 Installation ...
Страница 76: ...76 Configuration ...
Страница 104: ...104 Operation and management ...
Страница 140: ...140 Regulatory compliance and safety ...
Страница 152: ...152 MSA1510i worksheets ...