Message
Type
Description
Action
450 INVALID SCSI
CABLING BOX #<n>
Error
The MSA has detected an external
storage enclosure that is cabled
incorrectly.
Verify that the external storage
enclosures are connected properly
to the MSA. For more information,
see the MSA installation guide.
500 INITIALIZING
PCI SUBSYSTEM
Informational
The array controller's PCI subsystem
is being initialized as part of the
power up sequence.
501 PCI SUBSYSTEM
HARDWARE FAILURE
Error
The array controller's PCI subsystem
has encountered a critical error
during the power-up sequence.
Remove the failed array controller,
wait 10 seconds, and then reinsert
the array controller, ensuring that it
is fully seated in the chassis.
If the issue persists, contact HP
support.
502 PCI BRIDGE
ASIC SELF TEST
FAILURE
Error
The array controller's PCI bridge
ASIC has encountered a critical
error during the power-up
sequence.
Remove the failed array controller,
wait 10 seconds, and then reinsert
the array controller, ensuring that it
is fully seated in the chassis.
If the issue persists, contact HP
support.
512 ECC CORRECTED
MEMORY ERROR SEEN
Error
The array controller has detected
an uncorrectable ECC error in the
data cache memory.
Contact HP support.
513 UNCORRECTED
ECC MEMORY ERROR
SEEN
Error
The array controller has detected
an uncorrectable error in the ECC
memory on the memory cache
board.
Remove the failed array controller
and replace the memory cache
board with a new one.
518 PERSISTENT MEM
ENABLED
Informational
Global variables such as system
prompts and pro
fi
le information
remain persistent in cache over
power cycles of the system. This
message is displayed each time
the MSA is powered on.
519 PERSISTENT MEM
DISABLED
Informational
Persistent memory data has not
been successfully initialized.
Some con
fi
guration data may not
be available.
520 UNKNOWN I/O
MODULE DETECTED
Error
The MSA cannot determine the
type of I/O module installed in the
bay.
Do the following:
1.
Remove power from any
external storage enclosures.
2.
Remove power from the MSA.
3.
Reseat all I/O modules.
4.
Apply power to any external
storage enclosures.
5.
Apply power to the MSA.
6.
Verify that the MSA has
the latest version
fi
rmware
installed.
Should the issue persist, contact
HP support.
521 ISCSI PARAM
LOAD ERROR
Error
An error occurred while
programming iSCSI con
fi
guration
to the iSCSI hardware.
Contact HP support if the problem
persists.
126
MSA controller LCD panel message descriptions
Содержание StorageWorks 1510i - Modular Smart Array
Страница 8: ...8 ...
Страница 58: ...58 Installation ...
Страница 76: ...76 Configuration ...
Страница 104: ...104 Operation and management ...
Страница 140: ...140 Regulatory compliance and safety ...
Страница 152: ...152 MSA1510i worksheets ...