Message
Type
Description
Action
88 NON-HP DRIVE
BOX #<n>, BAY <n>
Informational
An unsupported hard drive is
located in the indicated bay of the
storage enclosure.
89 INVALID CONFIG
BOX #<n>, BAY <n>
Error
The indicated hard drive contains
unrecognized con
fi
guration
information from another system
and therefore will not be used.
Replace the indicated hard drive.
100 VOLUME #<n>
STATE OK
Informational
The con
fi
gured volume has
returned to its normal operating
state. This typically occurs after a
rebuild operation has completed.
101 VOLUME #<n>
STATE FAILED
Error
The con
fi
gured volume has been
failed because too many SCSI
hard drives that it is composed of
have failed, exceeding the fault
tolerance level. The data on the
con
fi
gured volume is no longer
available. There is a risk of data
loss.
Replace the failed hard drives as
soon as possible. If necessary,
restore data from backup.
102 VOLUME #<n>
STATE INTERIM
RECOVERY
Informational
The array controller has failed one
or more SCSI hard drives that the
con
fi
gured volume is composed
of. No data loss has occurred
because fault tolerance is allowing
the data to be recovered.
Replace the failed hard drives as
soon as possible.
103 VOLUME #<n>
STATE REBUILDING
Informational
The con
fi
gured volume is rebuilding
data on a SCSI drive that replaced
a previously failed drive.
104 VOLUME #<n>
STATE DISABLED
Error
The con
fi
gured volume has been
disabled because too many of
the SCSI hard drives that it is
composed of are missing.
Power off the MSA and all attached
external storage enclosures.
Unplug and reinsert all SCSI hard
drives, ensuring they are fully
seated in their bays. Check the
cables connecting the MSA to
any attached storage enclosures.
Power on the attached storage
enclosures and then the MSA.
105 VOLUME #<n>
STATE EXPANSION
ACTIVE
Informational
The con
fi
gured volume is currently
performing a volume expansion
operation.
106 VOLUME #<n>
STATE WAITING TO
REBUILD
Informational
The con
fi
gured volume is waiting
to start rebuilding data on a SCSI
drive that replaces a previously
failed drive. The rebuild may not
have started yet because the array
controller is already performing
a rebuild on another con
fi
gured
volume.
107 VOLUME #<n>
STATE WAITING TO
EXPAND
Informational
The con
fi
gured volume is waiting
to start a volume expansion
operation. The expansion may
have not started yet because
another con
fi
gured volume is
undergoing expansion or a rebuild
is occurring on the con
fi
gured
volume.
118
MSA controller LCD panel message descriptions
Содержание StorageWorks 1510i - Modular Smart Array
Страница 8: ...8 ...
Страница 58: ...58 Installation ...
Страница 76: ...76 Configuration ...
Страница 104: ...104 Operation and management ...
Страница 140: ...140 Regulatory compliance and safety ...
Страница 152: ...152 MSA1510i worksheets ...