Installing Hardware Options
12.
Reinstall the air baffle.
13.
Reinstall the memory board.
a.
Align the memory board with the memory slot and memory board guide
clips.
b.
Slide the memory board into the server
(1)
and close the ejector levers to seat
the memory board firmly
(2)
.
c.
Engage the locking switch
(3).
Figure 5-22: Reinstalling the memory board
14.
Close the rear access panel.
15.
Restore the server to its operating position in the rack.
16.
Power up the server. Refer to Chapter 9, “Server Setup.”
NOTE:
The ROM sets the processing frequency during the Power-On Self-Test (POST).
17.
Be sure that the internal health LED on the front of the system is illuminated
green, indicating that the system is functioning properly. For detailed information
on LEDs, refer to Appendix E, “System LEDs and Switches.”
18.
If the LED indicates an error, refer to Appendix H, “Troubleshooting,” or refer to
the
HP Servers Troubleshooting Guide
on the Documentation CD for
instructions.