Troubleshooting
Table H-5: Is the Internal Health LED Green?
Answer Possible
Reasons Possible
Solutions
For component failure identification (amber LED), check the hood label.
No, it is
amber
A processor is in pre-failure
condition.
A DIMM is in pre-failure
condition.
One memory bank is valid, but
another bank is missing a DIMM.
One memory bank is valid, but
another bank has mismatched
DIMMs installed.
One memory bank is valid, but
another bank has an
unsupported DIMM type installed.
A redundant fan has failed.
Use internal component failure LEDs to
identify:
•
Missing components
•
Degraded components
•
Failed components
•
Improperly installed components
For corrective procedures, refer to the
maintenance and service guide on the
Documentation CD that ships with the
server.
Contact an authorized service provider for
replacement parts and service.
continued
HP ProLiant DL580 Generation 2 Server Setup and Installation Guide
H-9
HP CONFIDENTIAL
Writer: Karen Hale File Name: s-apph Troubleshooting.doc
Codename: Wave Part Number: 230835-003 Last Saved On: 6/26/03 9:52 AM