14.
If this is the only Failover manager you are installing, select
No, I am done
and click
Next
.
NOTE:
If you want to install another Failover Manager, the wizard repeats the steps, using
information you already entered, as appropriate.
15.
Finish the installation, reviewing the configuration summary, and click
Deploy
.
When the installer is finished, the Failover Manager is ready to be used in the HP LeftHand
Storage.
After installation, click
Find
→
Find Systems
in the CMC and enter the Failover Manager IP address
to discover the Failover Manager, and then add it to a management group. See
“Adding a storage
system to an existing management group” (page 112)
for more information.
Installing the Failover Manager for other VMware platforms
1.
Insert the DVD in the DVD drive (either the physical HP LeftHand Virtual SAN Appliance and
Failover Manager DVD you received or the DVD you created after downloading the DVD
.iso
image from the web).
2.
Locate the applicable executable and double-click it to begin.
3.
Click
Agree
to accept the terms of the License Agreement.
4.
Click
Failover Manager
→
Install FOM for other VMware platforms
to begin the wizard.
5.
Accept the terms of the License Agreement, and click
Next
.
6.
Accept the default location to install the files, or change the location, and click
Next
.
7.
To complete the installation, click
Finish
.
Configuring the IP address and host name
1.
In the VMware application, navigate to the location of the Failover Manager and start the
virtual machine.
2.
Wait for the Failover Manager to boot.
3.
When the Failover Manager finishes booting, enter
Start
and press
Enter
to log in to the
Configuration Interface.
4.
On the main menu, press
Tab
to navigate to
Network TCP/IP Settings
and press
Enter
.
5.
On the Available Network Devices window, press
Tab
to navigate to the network interface
and press
Enter
.
6.
On the Network Settings window, press
Tab
to navigate to the
Hostname
field. Press
Backspace
to erase an entry if necessary. Enter a host name for the Failover Manager.
This host name displays in the CMC only. It does not change the name of the original
.VMX
file or the name of the virtual machine in the VMware interface.
7.
Press
Tab
to navigate to the method for setting the IP address.
If you are entering a static IP address, Gateway is a required field. If you do not have a
gateway, enter 0.0.0.0.
8.
Press
Tab
to navigate to
OK
and press
Enter
.
9.
Press
Enter
again to confirm the action.
10.
After the settings are configured, press
Enter
to confirm the IP address change.
11.
On the Available Network Devices window, press
Tab
to navigate to
Back
and press
Enter
.
12.
On the Configuration Interface, press
Tab
to navigate to
Log Out
and press
Enter
.
After installation, click
Find
→
Find Systems
in the CMC and enter the Failover Manager IP address
to discover the Failover Manager, and then add it to a management group. See
“Adding a storage
system to an existing management group” (page 112)
for more information.
124
Working with managers and quorum