Tape Drives: Monitoring and Recovery
HP Integrity NonStop NS-Series Operations Guide — 529869-005
11- 5
Monitoring Tape Drive Status With SCF
Monitoring Tape Drive Status With SCF
To check the status of all tape drives on your system with SCF:
> SCF STATUS TAPE $*
A listing similar to this one is sent to your home terminal:
The data shown in the report means:
For more information:
•
SCF Object States
on page 3-14 describes the possible SCF states of tape drives
and other devices.
•
The
Guardian User’s Guide
provides additional information about tape operations
and the tasks you can perform.
Example
To obtain status information about the tape drive $TAPE0 by using SCF:
> SCF STATUS TAPE $TAPE0
A listing such as this one is sent to your home terminal:
STORAGE - Status TAPE \MINDEN.$XTAPE
LDev State Primary Backup DeviceStatus
PID PID
93 STOPPED 1,287 0,279 NOT READY
STORAGE - Status TAPE \MINDEN.$TAPE0
LDev State Primary Backup DeviceStatus
PID PID
99 STARTED 1,289 0,278 NOT READY
LDev
The logical device number
State
The current SCF state of the tape path
SubState
The current SCF substate of the tape path
Primary PID
The primary processor number and process identification number
(PIN) of the specified device
Backup PID
The backup processor number and PIN of the specified device
DeviceStatus
The status of the device path
STORAGE - Status TAPE \MINDEN.$TAPE0
LDev State Primary Backup DeviceStatus
PID PID
99 STARTED 1,289 0,278 NOT READY
Содержание Integrity NonStop NS-series
Страница 150: ...Disk Drives Monitoring and Recovery HP Integrity NonStop NS Series Operations Guide 529869 005 10 16 Related Reading ...
Страница 176: ...Power Failures Preparation and Recovery HP Integrity NonStop NS Series Operations Guide 529869 005 14 6 Related Reading ...
Страница 224: ...Creating Startup and Shutdown Files HP Integrity NonStop NS Series Operations Guide 529869 005 16 24 TMF Shutdown File ...
Страница 242: ...Related Reading HP Integrity NonStop NS Series Operations Guide 529869 005 C 6 ...
Страница 252: ...Converting Numbers HP Integrity NonStop NS Series Operations Guide 529869 005 D 10 Decimal to Hexadecimal ...
Страница 258: ...Safety and Compliance Statements 6 Important Safety Information ...
Страница 266: ...Index HP Integrity NonStop NS Series Operations Guide 529869 005 Index 8 Special Characters ...