IMPORTANT:
You must compile and manually register the StoreAll MIB file by using HP Systems
Insight Manager:
1.
Download
ibrixMib.txt
from
/usr/local/ibrix/doc/
.
2.
Rename the file to
ibrixMib.mib
.
3.
In HP Systems Insight Manager, complete the following steps:
a.
Unregister the existing MIB by entering the following command:
<BASE>\mibs>mxmib -d ibrixMib.mib
b.
Copy the
ibrixMib.mib
file to the
<BASE>\mibs
directory, and then enter the following
commands:
<BASE>\mibs>mcompile ibrixMib.mib
<BASE>\mibs>mxmib -a ibrixMib.cfg
For more information about the MIB, see the "Compiling and customizing MIBs" chapter in the HP
Systems Insight Manager User Guide, which is available at:
http://www.hp.com/go/insightmanagement/sim/
Click
Support & Documents
and then click
Manuals
. Navigate to the user guide.
Limitations
Note the following:
•
For StoreAll systems, the HP Insight Remote Support implementation is limited to hardware
events.
•
The X9720 CX storage device is not supported for HP Insight Remote Support.
Configuring the StoreAll cluster for Insight Remote Support
To enable X9720/9730 systems for remote support, you need to configure the Virtual SAS Manager,
Virtual Connect Manager, and Phone Home settings. All nodes in the cluster should be up when
you perform this step.
NOTE:
Configuring Phone Home removes any previous StoreAll
snmp
configuration details and
populates the SNMP configuration with Phone Home configuration details. When Phone Home is
enabled, you cannot use
ibrix_snmpagent
to edit or change the
snmp
agent configuration.
However, you can use
ibrix_snmptrap
to add trapsink IPs and you can use
ibrix_event
to
associate events to the trapsink IPs.
Registering Onboard Administrator
The Onboard Administrator is registered automatically.
Configuring the Virtual SAS Manager
On 9730 systems, the SNMP service is disabled by default on the SAS switches. To enable the
SNMP service manually and provide the trapsink IP on all SAS switches, complete these steps:
1.
Open the Virtual SAS Manager from the OA. Select
OA IP
>
Interconnect Bays
>
SAS Switch
>
Management Console
.
2.
On the Virtual SAS Manager, open the
Maintain
tab, click
SAS Blade Switch
, and select
SNMP
Settings
. On the dialog box, enable the SNMP service and supply the information needed for
alerts.