2.
Move the
<installer_dir>/ibrix
directory used in the previous release installation to
ibrix.old
. For example, if you expanded the tarball in
/root
during the previous StoreAll
installation on this node, the installer is in
/root/ibrix
.
3.
Expand the distribution tarball or mount the distribution DVD in a directory of your choice.
Expanding the tarball creates a subdirectory named
ibrix
that contains the installer program.
For example, if you expand the tarball in
/root
, the installer is in
/root/ibrix
.
4.
Change to the installer directory if necessary and execute the following command:
./ibrixupgrade -f
5.
Verify that the management console started successfully:
/etc/init.d/ibrix_fusionmanager status
The status command confirms whether the correct services are running. Output is similar to
the following:
Fusion Manager Daemon (pid 18748) running...
6.
Check
/usr/local/ibrix/log/fusionserver.log
for errors.
Upgrading the file serving nodes
After the management console has been upgraded, complete the following steps on each file
serving node:
1.
Move the
<installer_dir>/ibrix
directory used in the previous release installation to
ibrix.old
. For example, if you expanded the tarball in
/root
during the previous StoreAll
installation on this node, the installer is in
/root/ibrix
.
2.
Expand the distribution tarball or mount the distribution DVD in a directory of your choice.
Expanding the tarball creates a subdirectory named
ibrix
that contains the installer program.
For example, if you expand the tarball in
/root
, the installer is in
/root/ibrix
.
3.
Change to the installer directory if necessary and execute the following command:
./ibrixupgrade -f
The upgrade automatically stops services and restarts them when the process completes.
4.
When the upgrade is complete, verify that the StoreAll software services are running on the
node:
/etc/init.d/ibrix_server status
The output should be similar to the following example. If the IAD service is not running on your
system, contact HP Support.
IBRIX Filesystem Drivers loaded
ibrcud is running.. pid 23325
IBRIX IAD Server (pid 23368) running...
5.
Execute the following commands to verify that the
ibrix
and
ipfs
services are running:
lsmod|grep ibrix
ibrix 2323332 0 (unused)
lsmod|grep ipfs
ipfs1 102592 0 (unused)
If either
grep
command returns empty, contact HP Support.
6.
From the management console, verify that the new version of StoreAll software FS/IAS has
been installed on the file serving nodes:
<ibrixhome>/bin/ibrix_version -l -S
Completing the upgrade
1.
Remount all file systems:
<ibrixhome>/bin/ibrix_mount -f <fsname> -m </mountpoint>
Upgrading the StoreAll software to the 5.5 release
193