background image

HP IBRIX X9720/StoreAll 9730 Storage
Administrator Guide

Abstract

This guide describes tasks related to cluster configuration and monitoring, system upgrade and recovery, hardware component
replacement, and troubleshooting. It does not document StoreAll file system features or standard Linux administrative tools and
commands. For information about configuring and using StoreAll file system features, see the

nl

HP StoreAll Storage File System User Guide

.

This guide is intended for system administrators and technicians who are experienced with installing and administering networks,
and with performing Linux operating and administrative tasks. For the latest StoreAll guides, browse to

nl

http://www.hp.com/support/StoreAllManuals

.

HP Part Number: AW549-96073
Published: Ju

ly

2013

Edition: 1

4

Содержание IBRIX X9720

Страница 1: ...dministrative tools and commands For information about configuring and using StoreAll file system features see the nl HP StoreAll Storage File System User Guide This guide is intended for system administrators and technicians who are experienced with installing and administering networks and with performing Linux operating and administrative tasks For the latest StoreAll guides browse to nl http w...

Страница 2: ...about NDMP backups and configuring virtual interfaces and updated cluster procedures 5 5 December 2010 5 Updated segment evacuation information 5 5 March 201 1 6 Revised upgrade procedure 5 6 April 201 1 7 Added or updated information about the agile Fusion Manager Statistics tool Ibrix Collect event notification capacity block installation NTP servers upgrades 6 0 September 201 1 8 Added or updat...

Страница 3: ... Query enabled file systems 20 Troubleshooting upgrade issues 21 Automatic upgrade 21 Manual upgrade 22 Offline upgrade fails because iLO firmware is out of date 22 Node is not registered with the cluster network 22 File system unmount issues 23 File system in MIF state after StoreAll software 6 3 upgrade 23 2 Product description 25 System features 25 System components 25 HP StoreAll software feat...

Страница 4: ...over 53 Viewing information about Fusion Managers 54 Configuring High Availability on the cluster 54 What happens during a failover 55 Configuring automated failover with the HA Wizard 55 Configuring automated failover manually 62 Changing the HA configuration manually 63 Failing a server over manually 64 Failing back a server 64 Setting up HBA monitoring 65 Checking the High Availability configur...

Страница 5: ...for a storage cluster 96 Monitoring pools for a storage cluster 99 Monitoring storage controllers for a storage cluster 100 Monitoring storage switches in a storage cluster 101 Managing LUNs in a storage cluster 101 Monitoring the status of file serving nodes 102 Monitoring cluster events 103 Viewing events 103 Removing events from the events database table 104 Monitoring cluster health 104 Health...

Страница 6: ...131 Preferring network interfaces 131 Unpreferring network interfaces 132 Making network changes 132 Changing the IP address for a Linux StoreAll client 132 Changing the cluster interface 133 Managing routing table entries 133 Adding a routing table entry 133 Deleting a routing table entry 133 Deleting a network interface 133 Viewing network interface information 134 12 Licensing 135 Viewing licen...

Страница 7: ...ion 170 Obtaining spare parts 171 HP websites 171 Rack stability 171 Product warranties 171 Subscription service 171 17 Documentation feedback 173 A Cascading Upgrades 174 Upgrading the StoreAll software to the 6 1 release 174 Upgrading 9720 chassis firmware 175 Online upgrades for StoreAll software 6 x to 6 1 175 Preparing for the upgrade 175 Performing the upgrade 176 After the upgrade 176 Offli...

Страница 8: ...2 connections to the SAS switches 204 StoreAll 9730 CX 3 connections to the SAS switches 205 StoreAll 9730 CX 7 connections to the SAS switches in the expansion rack 206 C The IBRIX X9720 component and cabling diagrams 207 Base and expansion cabinets 207 Front view of a base cabinet 207 Back view of a base cabinet with one capacity block 208 Front view of a full base cabinet 209 Back view of a ful...

Страница 9: ...g methods 220 Equipment symbols 221 Weight warning 221 Rack warnings and precautions 221 Device warnings and precautions 222 E Regulatory information 224 Belarus Kazakhstan Russia marking 224 Turkey RoHS material content declaration 224 Ukraine RoHS material content declaration 224 Warranty information 224 Glossary 225 Index 227 Contents 9 ...

Страница 10: ...des hosting the agile Fusion Manager be registered on the cluster network Run the following command to verify that nodes hosting the agile Fusion Manager have IP addresses on the cluster network 4 ibrix_fm l If a node is configured on the user network see Node is not registered with the cluster network page 22 for a workaround NOTE The Fusion Manager and all file serving nodes must be upgraded to ...

Страница 11: ... StoreAll software later in this chapter this folder must contain only rpm packages listed in the build manifest for the upgrade or the upgrade will fail 2 Mount the pkg full ISO image and copy the entire directory structure to the local ibrix directory as shown in the following example mount o loop local pkg ibrix pkgfull FS_6 3 72 IAS_6 3 72 x86_64 signed iso mnt 3 Execute the firmware binary at...

Страница 12: ...x or earlier and you have one or more Express Query enabled file system each one needs to be manually upgraded as described in Upgrading pre 6 3 Express Query enabled file systems page 19 14 IMPORTANT Run the steps in Required steps before the StoreAll Upgrade for pre 6 3 Express Query enabled file systems page 19 before the upgrade This section provides steps for saving your custom metadata and a...

Страница 13: ... for the NIC or HBA Monitored columns see the sections for ibrix_nic m h host A node_2 node_interface and ibrix_hba m h host p World_Wide_Name in the CLI guide for your current release Performing the upgrade The online upgrade is supported only from the StoreAll 6 x releases IMPORTANT Complete all steps provided in the Table 1 page 10 Complete the following steps 1 This release is only available t...

Страница 14: ...r to version 6 3 manually complete each file system upgrade as described in Required steps after the StoreAll Upgrade for pre 6 3 Express Query enabled file systems page 20 Automated offline upgrades for StoreAll software 6 x to 6 3 Preparing for the upgrade To prepare for the upgrade complete the following steps 1 Make sure you have completed all steps in the upgrade checklist Table 1 page 10 2 S...

Страница 15: ...aining the files must be upgraded for snapshots To upgrade a file system use the upgrade60 sh utility For more information see Upgrading pre 6 0 file systems for software snapshots page 180 Data retention Files used for data retention including WORM and auto commit must be created on StoreAll software 6 1 1 or later or the pre 6 1 1 file system containing the files must be upgraded for retention f...

Страница 16: ...ms on Linux StoreAll clients ibrix_umount f MOUNTPOINT 12 Stop the SMB NFS and NDMP services on all nodes Run the following commands on the node hosting the active Fusion Manager ibrix_server s t cifs c stop nl ibrix_server s t nfs c stop nl ibrix_server s t ndmp c stop If you are using SMB verify that all likewise services are down on all file serving nodes ps ef grep likewise Use kill 9 to stop ...

Страница 17: ...y stops the necessary services and restarts them when the upgrade is complete The upgrade script installs the Fusion Manager on the server 6 After completing the previous steps for the server running the active Fusion Manager repeat the steps for each of the servers running the passive Fusion Manager 7 Upgrade Linux StoreAll clients See Upgrading Linux StoreAll clients page 18 8 If you received a ...

Страница 18: ...grade a file system use the ibrix_reten_adm u f FSNAME command Additional steps are required before and after you run the ibrix_reten_adm u f FSNAME command For more information see Upgrading pre 6 1 1 file systems for data retention features page 181 1 1 If you have an Express Query enabled file system prior to version 6 3 manually complete each file system upgrade as described in Required steps ...

Страница 19: ...e Directory Settings tab click Update to retrieve the current Active Directory settings 7 Mount file systems using the StoreAll Windows client GUI NOTE If you are using Remote Desktop to perform an upgrade you must log out and log back in to see the drive mounted Upgrading pre 6 3 Express Query enabled file systems The internal database schema format of Express Query enabled file systems changed b...

Страница 20: ... the following command ibrix_archiving S F 8 delete the internal database files for this file system by entering the following command rm rf FS_MOUNTPOINT archiving database In this instance FS_MOUNTPOINT is the file system mount point Required steps after the StoreAll Upgrade for pre 6 3 Express Query enabled file systems These steps are required after the StoreAll Upgrade 1 Restart the Archiving...

Страница 21: ... Restore your custom metadata by entering the following command MDImport f FSNAME n tmp custAttributes csv t custom In this instance FSNAME is the file system Troubleshooting upgrade issues If the upgrade does not complete successfully check the following items For additional assistance contact HP Support Automatic upgrade Check the following If the initial execution of usr local ibrix setup upgra...

Страница 22: ... is out of date If the iLO2 firmware is out of date on a node the auto_ibrixupgrade script will fail The usr local ibrix setup logs auto_ibrixupgrade log reports the failure and describes how to update the firmware After updating the firmware run the following command on the node to complete the StoreAll software upgrade local ibrix ibrixupgrade f Node is not registered with the cluster network No...

Страница 23: ...config ibrix_ndmp off chkconfig ibrix_fusionmanager off 2 Reboot all servers 3 Run the following commands to move the services back to the on state The commands do not start the services chkconfig ibrix_server on chkconfig ibrix_ndmp on chkconfig ibrix_fusionmanager on 4 Run the following commands to start the services service ibrix_fusionmanager start service ibrix_server start 5 Unmount the file...

Страница 24: ... database In this instance FS_MOUNTPOINT is the file system mount point 4 Clear the MIF condition by running the following command ibrix_archiving C FSNAME In this instance FSNAME is the file system 5 Re enable Express Query on the file systems ibrix_fs T E f FSNAME In this instance FSNAME is the file system Express Query will begin resynchronizing repopulating a new database for this file system ...

Страница 25: ... and cabling diagrams page 201 For information about X9720 system components and cabling see The IBRIX X9720 component and cabling diagrams page 207 For a complete list of system components see the HP StoreAll Storage QuickSpecs which are available at http www hp com go StoreAll HP StoreAll software features HP StoreAll software is a scale out network attached storage solution including a parallel...

Страница 26: ...y for maintenance operations and then returned to the file system To ensure continuous data access StoreAll software provides manual and automated failover protection at various points Server A failed node is powered down and a designated standby server assumes all of its segment management duties Segment Ownership of each segment on a failed node is transferred to a designated standby server Netw...

Страница 27: ...plementation to validate that prerequisites have been met Validate that your file system performance availability and manageability requirements have not changed since the service planning phase Finalize the HP Enterprise NAS product implementation plan and software configuration Implement the documented and agreed upon configuration based on the information you provided on the pre delivery checkl...

Страница 28: ...t Unicode Transformation Format encoding for supported locales This allows you to create edit and view documents written in different locales using UTF 8 StoreAll software supports modifying the etc sysconfig i18n configuration file for your locale The following example sets the LANG and SUPPORTED variables for multiple character sets LANG ko_KR utf8 SUPPORTED en_US utf8 en_US en ko_KR utf8 ko_KR ...

Страница 29: ...t interfaces Cluster operations are managed through the StoreAll Fusion Manager which provides both a Management Console and a CLI Most operations can be performed from either the StoreAll Management Console or the CLI The following operations can be performed only from the CLI SNMP configuration ibrix_snmpagent ibrix_snmpgroup ibrix_snmptrap ibrix_snmpuser ibrix_snmpview Health checks ibrix_hacon...

Страница 30: ...e prompts for your user name and password The default administrative user is ibrix Enter the password that was assigned to this user when the system was installed You can change the password using the Linux passwd command To allow other users to access the Management Console see Adding user accounts for Management Console access page 33 Upon login the Management Console dashboard opens allowing yo...

Страница 31: ...at change the cluster Examples are mounting a file system or creating a segment Cluster Overview The Cluster Overview provides the following information Capacity The amount of cluster storage space that is currently free or in use File systems The current health status of the file systems in the cluster The overview reports the number of file systems in each state healthy experiencing a warning ex...

Страница 32: ...configuration to add view or change cluster objects such as file systems or storage and to initiate or view tasks such as snapshots or replication When you select an object a details page shows a summary for that object The lower Navigator allows you to view details for the selected object or to initiate a task In the following example we selected Filesystems in the upper Navigator and Mountpoints...

Страница 33: ... are created when StoreAll software is installed The following entries in the etc group file show the default users in these groups ibrix admin x 501 root ibrix ibrix user x 502 ibrix ibrixUser ibrixuser You can add other users to these groups as needed using Linux procedures For example adduser G ibrix groupname username When using the adduser command be sure to include the G option Using the CLI...

Страница 34: ...emote Desktop to access the client and the drive letter does not appear log out and log in again Umount Unmounts a file system Tune Host Tunable parameters include the NIC to prefer the client uses the cluster interface by default unless a different network interface is preferred for it the communications protocol UDP or TCP and the number of server threads to use Active Directory Settings Display...

Страница 35: ... networks however you can limit ICMP to types 0 3 8 and 1 1 if necessary Be sure to open the ports listed in the following table Description Port SSH 22 tcp SSH for Onboard Administrator OA only for X9720 9730 blades 9022 tcp NTP 123 tcp 123 upd Multicast DNS 224 0 0 251 5353 udp netperf tool 12865 tcp Fusion Manager to file serving nodes 80 tcp 443 tcp Fusion Manager and StoreAll file system 5432...

Страница 36: ...n Manager node synchronizes its time with the external source The other file serving nodes synchronize their time with the active Fusion Manager node In the absence of an external time source the local hardware clock on the agile Fusion Manager node is used as the time source This configuration method ensures that the time is synchronized on all cluster nodes even in the absence of an external tim...

Страница 37: ...t Advanced IRSA This version is integrated with HP Systems Insight Manager SIM It provides comprehensive remote monitoring notification advisories dispatch and proactive service support IRSA and HP SIM together are referred to as the CMS The Phone Home configuration does not support backup or standby NICs that are used for NIC failover If backup NICs are currently configured remove the backup NICs...

Страница 38: ...te Support To enable X9720 9730 systems for remote support you need to configure the Virtual SAS Manager Virtual Connect Manager and Phone Home settings All nodes in the cluster should be up when you perform this step NOTE Configuring Phone Home removes any previous StoreAll snmp configuration details and populates the SNMP configuration with Phone Home configuration details When Phone Home is ena...

Страница 39: ... Bays HP VC Flex 10 Management Console 2 On the HP Virtual Connect Manager open the SNMP Configuration tab 3 Configure the SNMP Trap Destination Enter the Destination Name and IP Address the CMS IP Select SNMPv1 as the SNMP Trap Format Specify public as the Community String 4 Select all trap categories VCM traps and trap severities Configuring HP Insight Remote Support on StoreAll systems 39 ...

Страница 40: ... settings To configure Phone Home on the GUI select Cluster Configuration in the upper Navigator and then select Phone Home in the lower Navigator The Phone Home Setup panel shows the current configuration 40 Getting started ...

Страница 41: ...olorado Next configure Insight Remote Support for the version of HP SIM you are using HP SIM 7 1 and IRS 5 7 See Configuring Insight Remote Support for HP SIM 7 1 and IRS 5 7 page 41 HP SIM 6 3 and IRS 5 6 See Configuring Insight Remote Support for HP SIM 6 3 and IRS 5 6 page 44 Configuring Insight Remote Support for HP SIM 7 1 and IRS 5 7 To configure Insight Remote Support complete these steps 1...

Страница 42: ...er g Customer Entered Product Number Enter the Host Name parameter exactly as it is listed by the ibrix_fm l command Entitle a chassis ibrix_phonehome e C OA IP Address of the Chassis b Customer Entered Serial Number g Customer Entered Product Number NOTE The Phone Home Storage selection on the GUI does not apply to X9720 9730 systems Discovering devices on HP SIM HP Systems Insight Manager SIM us...

Страница 43: ...n the Credentials SNMP tab This string should match the Phone Home read community string If the strings are not identical the Fusion Manager IP might be discovered as Unknown Configuring HP Insight Remote Support on StoreAll systems 43 ...

Страница 44: ...th the Fusion Manager IP address In HP SIM select Fusion Manager and open the Systems tab Then select Associations to view the devices You can view all StoreAll devices under Systems by Type Storage System Scalable Storage Solutions All X9000 Systems Configuring Insight Remote Support for HP SIM 6 3 and IRS 5 6 Discovering devices in HP SIM HP Systems Insight Manager SIM uses the SNMP protocol to ...

Страница 45: ...s on HP SIM 6 3 File serving nodes are discovered as ProLiant server Configuring device Entitlements Configure the CMS software to enable remote support for StoreAll systems For more information see Using the Remote Support Setting Tab to Update Your Client and CMS Information and Adding Individual Managed Systems in the HP Insight Remote Support Advanced A 05 50 Operations Guide Configuring HP In...

Страница 46: ...nd Site Information details Contract and Warranty Information Under Entitlement Information specify the Customer Entered serial number Customer Entered product number System Country code and Custom Delivery ID Verifying device entitlements To verify the entitlement information in HP SIM complete the following steps 1 Go to Remote Support Configuration and Services and select the Entitlement tab 2 ...

Страница 47: ...4 1 3 6 1 2 1 1 5 0 s test 1 3 6 1 4 1 232 11 2 11 1 0 i 0 1 3 6 1 4 1 232 11 2 8 1 0 s IBRIX remote support testing Updating the Phone Home configuration The Phone Home configuration should be synchronized after you add or remove devices in the cluster The operation enables Phone Home on newly added devices servers storage and chassis and removes details for devices that are no longer in the clus...

Страница 48: ...matches the Phone Home read community string Also run snmpwalk on the VIF IP and verify the information snmpwalk v 1 c read community string FM VIF IP 1 3 6 1 4 1 18997 Critical failures occur when discovering X9720 OA The 3GB SAS switches have internal IPs in the range 169 x x x which cannot be reached from HP SIM These switches will not be monitored however other OA components are monitored Disc...

Страница 49: ...er must be on the same network interface Also nodes set up as a failover pair must be connected to the same network interface Use a Gigabit Ethernet port or faster for user networks NFS SMB FTP and HTTP clients can use the same user VIF The servers providing the VIF should be configured in backup pairs and the NICs on those servers should also be configured for failover See Configuring High Availa...

Страница 50: ...c c n bond0 1 h node1 I 16 123 200 201 M 255 255 255 0 B 16 123 200 255 ibrix_nic c n bond0 1 h node2 I 16 123 200 202 M 255 255 255 0 B 16 123 200 255 ibrix_nic c n bond0 1 h node3 I 16 123 200 203 M 255 255 255 0 B 16 123 200 255 ibrix_nic c n bond0 1 h node4 I 16 123 200 204 M 255 255 255 0 B 16 123 200 255 Configuring backup servers The servers in the cluster are configured in backup pairs If ...

Страница 51: ... sample output shows only the relevant fields Specifying VIFs in the client configuration When you configure your clients you may need to specify the VIF that should be used for client access NFS SMB Specify the VIF IP address of the servers for example bond0 1 to establish connection You can also configure DNS round robin to ensure NFS or SMB client to server distribution In both cases the NFS SM...

Страница 52: ...n interface that has an associated VLAN tag In this case the device label of the interface takes the form bond VLAN_id VVIF_label For example if a VIF with a label of 2 is added for the bond0 30 interface the new interface device label will be bond0 30 2 The following commands show configuring a bonded VIF and backup nodes for a unified network topology using the 10 10 x y subnet VLAN tagging is c...

Страница 53: ...IST If the Fusion Manager was previously the active console StoreAll software will select a new active console A Fusion Manager currently in active mode can be moved to either passive or nofmfailover mode A Fusion Manager in nofmfailover mode can be moved only to passive mode With the exception of the local node running the active Fusion Manager the A option moves all instances of the Fusion Manag...

Страница 54: ...esignate the backup server as a standby NIC for bond0 2 If an issue occurs with bond0 2 on a server the server including its segment ownership and FM services will fail over to the backup server and that server will now handle SMB requests going through bond0 2 You can also fail over just the NIC to its standby NIC on the backup server HBA monitoring This method protects server access to storage t...

Страница 55: ...he operational status changes to Up FailedOver or Down FailedOver For more information about operational states see Monitoring the status of file serving nodes page 102 Both automated and manual failovers trigger an event that is reported on the GUI Automated failover can be configured with the HA Wizard or from the command line Configuring automated failover with the HA Wizard IMPORTANT On the X9...

Страница 56: ...on the dialog box When you have completed the information click Enable HA Monitoring and Auto Failover for both servers Use the NIC HA Setup dialog box to configure NICs that will be used for data services such as SMB or NFS You can also designate NIC HA pairs on the server and its backup and enable monitoring of these NICs 56 Configuring failover ...

Страница 57: ...e dialog box for ib69s1 On the Add NIC dialog box enter a NIC name In our example the cluster uses the unified network and has only bond0 the active cluster FM IP We cannot use bond0 0 which is the management IP VIF We will create the VIF bond0 1 using bond0 as the base When you click OK the user VIF is created The new active user NIC appears on the NIC HA setup dialog box Configuring High Availab...

Страница 58: ...Next enable NIC monitoring on the VIF Select the new user NIC and click NIC HA On the NIC HA Config dialog box check Enable NIC Monitoring 58 Configuring failover ...

Страница 59: ...r ib69s2 The standby you specify must be available and valid To keep the organization simple we specified bond0 1 as the Name this matches the name assigned to the NIC on server ib69s1 When you click OK the NIC HA configuration is complete Configuring High Availability on the cluster 59 ...

Страница 60: ...l interface such eth4 and create a standby NIC on the backup server for it The NICs panel on the GUI shows the NICs on the selected server In the following example there are four NICs on server ib69s1 bond0 the active cluster FM IP bond0 0 the management IP VIF this server is hosting the active FM bond0 1 the NIC created in this example and bond0 2 a standby NIC for an active NIC on server ib69s2 ...

Страница 61: ... box allows you change the IP address and other NIC properties The NIC HA tab allows you to enable or disable HA monitoring and failover on the NIC and to change or remove the standby NIC To view the power source for a server select the server on the Servers panel and then select Power from the lower Navigator The Power Source panel shows the power source configured on the server when HA was confi...

Страница 62: ... node3 bond0 1 node4 bond0 2 nl ibrix_nic b H node4 bond0 1 node3 bond0 2 2 Identify power sources To implement automated failover perform a forced manual failover or remotely power a file serving node up or down you must set up programmable power sources for the nodes and their backups Using programmable power sources prevents a split brain scenario between a failing file serving node and its bac...

Страница 63: ...or for selected nodes Turn on automated failover ibrix_server m h SERVERNAME Changing the HA configuration manually Update a power source If you change the IP address or password for a power source you must update the configuration database with the changes The user name and password options are needed only for remotely managed power sources Include the s option to have the Fusion Manager skip BMC...

Страница 64: ... not complete contact HP Support for assistance For information about the values that can appear in the STATE field see What happens during a failover page 55 Failing back a server After an automated or manual failover of a server you must manually fail back the server which restores ownership of the failed over segments and network interfaces to the server Before failing back the server confirm t...

Страница 65: ...urviving port When monitoring is turned on for both ports the Fusion Manager initiates failover only when both ports in a pair fail When both HBA monitoring and automated failover for file serving nodes are configured the Fusion Manager will fail over a server in two situations Both ports in a monitored set of standby paired ports fail Because all standby pairs were identified in the configuration...

Страница 66: ...56 78 9a bc h s1 hp com Deleting HBAs from the configuration database Before switching an HBA to a different machine delete the HBA from the configuration database ibrix_hba d h HOSTNAME w WWNN Displaying HBA information Use the following command to view information about the HBAs in the cluster To view information for all hosts omit the h HOSTLIST argument ibrix_hba l h HOSTLIST The output includ...

Страница 67: ...nodes xs01 hp com and xs02 hp com ibrix_haconfig l h xs01 hp com xs02 hp com Host HA Configuration Power Sources Backup Servers Auto Failover Nics Monitored Standby Nics HBAs Monitored xs01 hp com FAILED PASSED PASSED PASSED FAILED PASSED FAILED xs02 hp com FAILED PASSED FAILED FAILED FAILED WARNED WARNED Viewing a detailed report Execute the ibrix_haconfig i command to view the detailed report ib...

Страница 68: ...system takes the following actions when a node fails 1 The Fusion Manager triggers a core dump on the failed node when failover starts changing the state of the node to Up InFailover 2 The failed node boots into the crash kernel The state of the node changes to Dumping InFailover 3 The failed node continues with the failover changing state to Dumping FailedOver 4 After the core dump is created the...

Страница 69: ...ntil the main menu is displayed Then at the main menu press F10 The server automatically restarts Setting up nodes for crash capture IMPORTANT Complete the steps in Prerequisites for setting up the crash capture page 68 before starting the steps in this section To set up nodes for crash capture complete the following steps 1 Enable crash capture Run the following command ibrix_host_tune S h HOSTLI...

Страница 70: ...is added using GUI nic removed NIC is removed using GUI physicalvolume added Physical storage is discovered and added using management console physicalvolume deleted Physical storage is deleted using management console You can be notified of cluster events by email or SNMP traps To view the list of supported events use the command ibrix_event q Setting up email notification of cluster events You c...

Страница 71: ...ddresses especially for the SMTP server If an address is not valid the SMTP server will reject the email The following command configures email settings to use the mail hp com SMTP server and turns on notifications ibrix_event m on s mail hp com f FM hp com r MIS hp com t Cluster1 Notification NOTE The state of the email notification process has no effect on the display of cluster events in the GU...

Страница 72: ...idated the VACM determines which managed objects these users are allowed to access The VACM includes an access scheme to control user access to managed objects context matching to define which objects can be accessed and MIB views defined by subsets of IOD subtree and associated bitmask entries which define what a particular user can access in the MIB Steps for setting up SNMP include Agent config...

Страница 73: ...f the agent s host name The format also provides the y and z options which determine whether a v3 agent can process v1 v2 read and write requests from the management station The format is ibrix_snmpagent u v 3 e engineId p PORT r READCOMMUNITY w WRITECOMMUNITY t SYSCONTACT n SYSNAME o SYSLOCATION y yes no z yes no c yes no s on off Configuring trapsink settings A trapsink is the host destination w...

Страница 74: ...ees and associated bitmasks that identify which subidentifiers are significant to the view s definition Using the bitmasks individual OID subtrees can be included in or excluded from the view An instance of a managed object belongs to a view if The OID of the instance has at least as many sub identifiers as the OID subtree in the view Each sub identifier in the instance and the subtree match when ...

Страница 75: ... optional An authentication password is required if the group has a security level of either authNoPriv or authPriv The privacy password is required if the group has a security level of authPriv If unspecified MD5 is used as the authentication algorithm and DES as the privacy algorithm with no passwords assigned For example to create user3 add that user to group2 and specify an authorization passw...

Страница 76: ...backup feature can be used to back up and recover entire StoreAll software file systems or portions of a file system You can use any supported NDMP backup application to perform the backup and recovery operations In NDMP terminology the backup application is referred to as a Data Management Application or DMA The DMA is run on a management station separate from the cluster and communicates with th...

Страница 77: ...nications between the DMA and the NDMP Servers in the cluster To configure the parameters on the GUI select Cluster Configuration from the Navigator and then select NDMP Backup The NDMP Configuration Summary shows the default values for the parameters Click Modify to configure the parameters for your cluster on the Configure NDMP dialog box See the online help for a description of each field Using...

Страница 78: ...ct NDMP Backup Active Sessions For each session the Active NDMP Sessions panel lists the host used for the session the identifier generated by the backup application the status of the session backing up data restoring data or idle the start time and the IP address used by the DMA To cancel a session select that session and click Cancel Session Canceling a session kills all spawned sessions process...

Страница 79: ...ibrix_event command INFO events Identifies when major NDMP operations start and finish and also report progress For example 7012 Level 3 backup of mnt ibfs7 finished at Sat Nov 7 21 20 58 PST 2011 7013 Total Bytes 38274665923 Average throughput 236600391 bytes sec WARN events Indicates an issue with NDMP access the environment or NDMP operations Be sure to review these events and take any necessar...

Страница 80: ...nt sets of clients To do this create a host group tree that includes the necessary host groups You can then assign the clients manually or the Fusion Manager can automatically perform the assignment when you register a StoreAll client based on the client s cluster subnet To use automatic assignment create a domain rule that specifies the cluster subnet for the host group Creating a host group tree...

Страница 81: ... to the finance group ibrix_hostgroup m g finance h cl01 hp com Adding a domain rule to a host group To configure automatic host group assignments define a domain rule for host groups A domain rule restricts host group membership to clients on a particular cluster subnet The Fusion Manager uses the IP address that you specify for clients when you register them to perform a subnet match and sorts t...

Страница 82: ...nds locally ibrix_lwmount a to force the client to pick up mounts or allocation policies ibrix_lwhost a to force the client to pick up host tunings To delete a host group using the CLI ibrix_hostgroup d g GROUPNAME Other host group operations Additional host group operations are described in the following locations Creating or deleting a mountpoint and mounting or unmounting a file system see Crea...

Страница 83: ...torage hardware components You can also drill down to view the status of individual chassis server and storage sub components Monitoring servers To view information about the server and chassis included in your system 1 Select Servers from the Navigator tree The Servers panel lists the servers included in each chassis 2 Select the server you want to obtain more information about Information about ...

Страница 84: ...Select the server component that you want to view from the lower Navigator panel such as NICs 84 Monitoring cluster operations ...

Страница 85: ...nd in Monitoring hardware components page 87 HBAs The HBAs panel displays the following information Node WWN Port WWN Backup Monitoring State NICs The NICs panel shows all NICs on the server including offline NICs The NICs panel displays the following information Name IP Type State Monitoring X9720 9730 hardware 85 ...

Страница 86: ... SMB yet CIFS is just a different name for SMB Name Value Power The Power panel displays the following information Host Name Type IP Address Slot ID Events The Events panel displays the following information Level Time Event Hardware The Hardware panel displays the following information The name of the hardware component The information gathered in regards to that hardware component See Monitoring...

Страница 87: ...VC modules and SAS switches The following Onboard Administrator view shows a chassis enclosure on a StoreAll 9730 system To monitor these components from the GUI 1 Click Servers from the upper Navigator tree 2 Click Hardware from the lower Navigator tree for information about the chassis that contains the server selected on the Servers panel as shown in the following image Monitoring X9720 9730 ha...

Страница 88: ...tatus Type Name UUID Serial number Detailed information of the hardware components in the blade enclosure is provided by expanding the Blade Enclosure node and clicking one of the sub nodes When you select one of the sub nodes under the Blade Enclosure node additional information is provided For example when you select the Fan node additional information about the Fan for the blade enclosure is pr...

Страница 89: ...The sub nodes under the Blade Enclosure node provide information about the hardware components within the blade enclosure Monitoring X9720 9730 hardware 89 ...

Страница 90: ...le or for the blade enclosure Status Type UUID Properties Fan The Fan panel displays information for a blade enclosure Status Type Name UUID Location Properties OA Module Status Type Name UUID Serial number Model Firmware version Location Properties Power Supply Status Type Name UUID Serial number Location Shared Interconnect Status Type Name UUID Serial number Model Firmware version Location Prop...

Страница 91: ... under the Hardware node The following overview information is provided for each server Status Type Name UUID Serial number Model Firmware version Message1 Diagnostic Message1 1 Column dynamically appears depending on the situation Obtain detailed information for hardware components in the server by clicking the nodes under the Server node Monitoring X9720 9730 hardware 91 ...

Страница 92: ... Location ILO Module Status Type Name UUID Serial Number Model Firmware Version Properties Memory DiMM Status Type Name UUID Location Properties NIC Status Type Name UUID Properties Power Management Controller Status Type Name UUID Firmware Version Storage Cluster Status Type Name UUID 92 Monitoring cluster operations ...

Страница 93: ...Type Name UUID Serial Number Model Firmware Version Location Message Diagnostic message Volume Displays volume information for each server Status Type Name UUID Properties Storage Controller Displayed for a storage cluster Status Type UUID Serial Number Model Firmware Version Message Diagnostic Message Battery Displayed for each storage controller Status Type UUID Properties IO Cache Module Displa...

Страница 94: ...tions Properties Monitoring storage and storage components Select Vendor Storage from the Navigator tree to display status and device information for storage and storage components The Vendor Storage panel lists the HP 9730 CX storage systems included in the system The Summary panel shows details for a selected vendor storage as shown in the following image 94 Monitoring cluster operations ...

Страница 95: ...er The Storage Cluster panel provides detailed information about the storage cluster See Monitoring storage clusters page 96 for more information Storage Switch The Storage Switch panel provides detailed information about the storage switches See Monitoring storage switches in a storage cluster page 101 for more information LUNs The LUNs panel provides information about the LUNs in a storage clust...

Страница 96: ... cluster Expand the Pool node to view information about the volumes in the pool See Monitoring pools for a storage cluster page 99 for more information Storage Controller The Storage Controller panel provides detailed information about the storage controller Expand the Storage Controller node to view information about batteries and IO cache modules for a storage controller See Monitoring storage c...

Страница 97: ... page 97 Power Supply Monitoring sub enclosures page 98 Sub Enclosure Monitoring the power supply for a storage cluster Each drive enclosure also has power supplies Select the Power Supply node to view the following information for each power supply in the drive enclosure Status Type Name UUID The Power Supply panel displayed in the following image provides information about four power supplies in...

Страница 98: ...er specifies the switch number and switch port For port 52 the drive is connected to port 2 on switch 5 For location Port 72 Box 1 Bay 6 the drive is connected to port 2 on switch 7 in bay 6 Properties Fan The Fan panel provides the following information about the fans in a sub enclosure Status Type Name UUID Properties SEP The SEP panel provides the following information about the storage enclose...

Страница 99: ... display information about that pool When you select the Pool node the following information is displayed in the Pool panel Status Type Name UUID Properties To obtain details on the volumes in the pool expand the Pool node and then select the Volume node The following information is displayed for the volume in the pool Status Type Name Monitoring X9720 9730 hardware 99 ...

Страница 100: ...ssage Expand the Storage Controller node to obtain information about the battery and IO cache module for the storage controller Monitoring the batteries for a storage controller The Battery panel displays the following information Status Type UUID Properties Provides information about the remaining charge and the charge status In the following image the Battery panel shows the information about a ...

Страница 101: ...view information about a storage enclosed processor SEP for a storage switch expand the Storage Switch node and select the SEP node The following information is provided for the SEP Status Type UUID Model Firmware Version In the following image the SEP panel displays the SEP processors for a storage switch Managing LUNs in a storage cluster The LUNs panel provides information about the LUNs in a s...

Страница 102: ...ver has encountered a condition that has been logged An event will appear in the Status tab of the GUI and an email notification may be sent Alert Up InFailover Server is powered on and visible to the Fusion Manager and the Fusion Manager is failing over the server s segments to a standby server Up FailedOver Server is powered on and visible to the Fusion Manager and failover is complete Down InFa...

Страница 103: ...he events You can also view events that have been reported for specific file systems or servers On the CLI use the ibrix_event command to view information about cluster events To view events by alert type use the following command ibrix_event q e ALERT WARN INFO The ibrix_event l command displays events in a short format event descriptions are truncated to fit on one line The n option specifies th...

Страница 104: ...ecause of a Linux or StoreAll software issue Remote servers that are not pingable might be down or have a network problem If test hosts are assigned to be network interface monitors pings their monitored interfaces to assess the health of the connection For information on network interface monitoring see Setting network interface options in the configuration database page 131 Determines whether sp...

Страница 105: ...v18 03 PASSED Server Up 10 10 18 3 Thu Oct 25 14 23 12 MDT 2012 bv18 04 PASSED Server Up 10 10 18 4 Thu Oct 25 14 23 22 MDT 2012 Viewing a detailed health report To view a detailed health report use the ibrix_health i command ibrix_health i h HOSTLIST f s v The f option displays results only for hosts that failed the check The s option includes information about the file system and its segments Th...

Страница 106: ...PASSED ibrixFS file system uuid matches on Iad and Fusion Manager PASSED ibrixFS file system generation matches on Iad and Fusion Manager PASSED ibrixFS file system number segments matches on Iad and Fusion Manager PASSED ibrixFS file system mounted state matches on Iad and Fusion Manager PASSED Superblock owner for segment 4 of filesystem ibrixFS on bv18 04 matches nl on Iad and Fusion Manager PA...

Страница 107: ...d MB s Read IO s Read ms op Write MB s Write IO s Write ms op lab12 10 hp com 22528 2 5 0 0 00 Net HOST In MB s In IO s Out MB s Out IO s lab12 10 hp com 261 3 355 2 Mem HOST MemTotal MB MemFree MB SwapTotal MB SwapFree MB lab12 10 hp com 1034616 703672 2031608 2031360 CPU HOST User System Nice Idle IoWait Irq SoftIrq lab12 10 hp com 0 0 0 0 97 1 0 NFS v3 HOST Null Getattr Setattr Lookup Access Re...

Страница 108: ...the file serving nodes to the active Fusion Manager Installing the Statistics tool The Statistics tool is installed automatically when the StoreAll software is installed on the file serving nodes To install or reinstall the Statistics tool manually use the following command ibrixinit tt Note the following Installation logs are located at tmp stats install log By default installing the Statistics t...

Страница 109: ...ts are moved from the var lib ibrix histstats folder to the local statstool histstats folder The upgrade retains the Statistics tool database but not the reports You can regenerate reports for the data stored before the upgrade by specifying the date range See Generating reports page 111 Using the Historical Reports GUI You can use the GUI to view or generate reports for the entire cluster or for ...

Страница 110: ...The Time View lists the reports in chronological order and the Table View lists the reports by cluster or server Click a report to view it 1 10 Using the Statistics tool ...

Страница 111: ... start the tool at 9 40 a m and ask for a report from 9 00 a m to 9 30 a m the report cannot be generated because data was not gathered for that period Reports are generated on an hourly basis It may take up to an hour before a report is generated and made available for viewing NOTE If the system is currently generating reports and you request a new report at the same time the GUI issues an error ...

Страница 112: ...ot need to restart the collection process collection continues automatically Changing the Statistics tool configuration You can change the configuration only on the management node To change the configuration add a configuration parameter and its value to the etc ibrix stats conf file on the currently active node Do not modify the etc ibrix statstool conf and etc ibrix statstool local conf files d...

Страница 113: ... Check the usr local ibrix log statstool stats log for any errors NOTE The reports generated before failover will not be available on the current active Fusion Manager Checking the status of Statistics tool processes To determine the status of Statistics tool processes run the following command etc init d ibrix_statsmanager status ibrix_statsmanager pid 25322 is running In the output the pid is th...

Страница 114: ...erving node If not see Enabling collection and synchronization page 108 Check for time synchronization All servers in the cluster should have the same date time and time zone to allow proper collection and viewing of reports Log files See usr local ibrix log statstool stats log for detailed logging for the Statistics tool The information includes detailed exceptions and traceback messages The logs...

Страница 115: ...c stop nl ibrix_server s t ndmp c stop If you are using SMB verify that all likewise services are down on all file serving nodes ps ef grep likewise Use kill 9 to stop any likewise services that are still running If you are using NFS verify that all NFS processes are stopped ps ef grep nfs If processes are running use the following commands on the affected node pdsh a service nfslock stop dshbak n...

Страница 116: ...down t now now 13 Use ping to verify that the nodes are down For example ping x850s2 nl PING x850s2 l3domain l3lab com 12 12 80 102 56 84 bytes of data nl x850s1 l3domain l3lab com 12 12 82 101 icmp_seq 2 Destination Host Unreachable If you are unable to shut down a node cleanly use the following command to power the node off using the iLO interface ibrix_server P off h HOSTNAME 14 Shut down the F...

Страница 117: ...hem all to report UP in the output from the following command ibrix_server l 4 Mount file systems and verify their content Run the following command on the file serving node hosting the active Fusion Manager ibrix_mount f fs_name m mountpoint On Linux StoreAll clients run the following command ibrix_lwmount f fsname m mountpoint 5 Enable HA on the file serving nodes Run the following command on th...

Страница 118: ...ng commands also control the operation of PostgreSQL on the machine The PostgreSQL service is available at usr local ibrix init To start and stop processes and view process status on the Fusion Manager use the following command etc init d ibrix_fusionmanager start stop restart status To start and stop processes and view process status on a file serving node use the following command In certain sit...

Страница 119: ... to tune one or more servers in the cluster To open the wizard select Servers from the Navigator and then click Tuning Options from the Summary panel The General Tunings dialog box specifies the communications protocol TCP or UDP and the number of admin and server threads The IAD Tunings dialog box configures the StoreAll administrative daemon Tuning file serving nodes and StoreAll clients 1 19 ...

Страница 120: ...e Module Tunings dialog box adjusts various advanced parameters that affect server operations On the Servers dialog box select the servers to which the tunings should be applied 120 Maintaining the system ...

Страница 121: ...T Contact HP Support to obtain the values for OPTIONLIST List the options as option value pairs separated by commas To set host tunings on all clients include the g clients option To reset host parameters to their default values on nodes or hostgroups ibrix_host_tune U h HOSTLIST g GROUPLIST n OPTIONS To reset all options on all file serving nodes hostgroups and StoreAll clients omit the h HOSTLIS...

Страница 122: ... StoreAll client GUI Tunable parameters include the NIC to prefer the default is the cluster interface the communications protocol UDP or TCP and the number of server threads to use See the online help for the client if necessary Managing segments When a file system is created the servers accessing the file system are assigned ownership of the storage segments used for the file system Each server ...

Страница 123: ... so that they can locate segments To migrate segments on the GUI select the file system on the Filesystems panel select Segments from the lower Navigator and then click Ownership Migration on the Segments panel to open the Segment Ownership Migration Wizard The Change Ownership dialog box reports the status of the servers in the cluster and lists the segments owned by each server In the Segment Pr...

Страница 124: ...ialog box shows the segment migration you specified Click Back to make any changes or click Finish to complete the operation To migrate ownership of segments from the CLI use the following commands Migrate ownership of specific segments ibrix_fs m f FSNAME s LVLIST h HOSTNAME M F N To force the migration include M To skip the source host update during the migration include F To skip server health ...

Страница 125: ...system Similarly if another task is running on the file system the evacuation task cannot be scheduled until the first task is complete The file system must be quiescent no active I O while a segment is being evacuated Running this utility while the file system is active may result in data inconsistency or loss To evacuate a segment complete the following steps 1 Identify the segment residing on t...

Страница 126: ...e data from the segment and click Destination If the file system is tiered be sure to select destination segments on the same tier as the source segment The Summary dialog box lists the source and destination segments for the evacuation Click Back to make any changes or click Finish to start the evacuation 126 Maintaining the system ...

Страница 127: ...amed Rebalance_ jobID FS ID info for example Rebalance_29 ibfs1 info Run the inum2name command to identify the symbolic name of the chunk file inum2name fsname ibfs 500000017 ibfs sliced_dir file3 bin After obtaining the name of the file use a command such as cp to move the file manually Then run the segment evacuation process again The analyzer log lists the chunks that were left on segments Foll...

Страница 128: ...s a large number of segments to be migrated and or segments can be migrated to several FSNs in SAN environments run the following command instead ibrix_fs m f ibfs1 s LVLIST h FSN_name 4 Remove the High Availability configuration between FSN4 and FSN3 a Stop NIC monitoring for the user NICs ibrix_nic m h FSN3 D FSN4 bond0 1 ibrix_nic m h FSN4 D FSN3 bond0 1 b Remove the backup NICs ibrix_nic b u F...

Страница 129: ...een file serving nodes and clients A cluster can have only one cluster interface For backup purposes each file serving node can have two cluster NICs User network interface This network interface carries traffic between file serving nodes and clients Multiple user network interfaces are permitted The cluster network interface was created for you when your cluster was installed A virtual interface ...

Страница 130: ...erface for a file serving node To identify a user network interface for specific file serving nodes use the ibrix_nic command The interface name IFNAME can include only alphanumeric characters and underscores such as eth1 ibrix_nic a n IFNAME h HOSTLIST If you are identifying a VIF add the VIF suffix nnnn to the physical interface name For example the following command identifies virtual interface...

Страница 131: ... for the network interface that has been preferred for it and then begins to use that interface If the services are already running on StoreAll clients when you prefer a network interface you can force clients to query the Fusion Manager by executing the command ibrix_lwhost a on the client or by rebooting the client Preferring a network interface for a file serving node or Linux StoreAll client T...

Страница 132: ...h3 Unpreferring network interfaces To return file serving nodes or StoreAll clients to the cluster interface unprefer their preferred network interface The first command unprefers a network interface for a file serving node the second command unprefers a network interface for a client ibrix_server n h SRCHOST D DESTHOST ibrix_client n h SRCHOST D DESTHOST To unprefer a network interface for a host...

Страница 133: ...k v cluster I Local IP address_or_DNS hostname Managing routing table entries StoreAll Software supports one route for each network interface in the system routing table Entering a new route for an interface overwrites the existing routing table entry for that interface Adding a routing table entry To add a routing table entry use the following command ibrix_nic r n IFNAME h HOSTNAME A R ROUTE The...

Страница 134: ...by network interface BACKUP IF File serving node HOST Network interface on this file serving node IFNAME IP address of this NIC IP_ADDRESS Whether monitoring is on for this NIC LINKMON MAC address of this NIC MAC_ADDR IP address in routing table used by this NIC ROUTE Network interface state STATE Network type cluster or user TYPE When ibrix_nic is used with the i option it reports detailed inform...

Страница 135: ...he Password Request Form that came with your License Entitlement Certificate See the certificate for fax numbers in your area Call or email the HP Password Center See the certificate for telephone numbers in your area or email addresses Using AutoPass to retrieve and install permanent license keys The procedure must be run from a client with JRE 1 5 or later installed and with a desktop manager ru...

Страница 136: ...d Severity How severe an upgrade is required Reboot required on flash Device information Parent device ID Components for firmware upgrades The HP StoreAll system includes several components with upgradable firmware The following lists the components that can be upgraded Server ILO2 9720 systems ILO3 BIOS Power_Mgmt_Ctlr Smart_Array_Ctlr NIC PCIeNIC SERVER_HDD Storage Enclosure_IO_Mod Enclosure_HDD...

Страница 137: ...g command to show which components could be flagged for flash upgrade hpsp_fmt lc The following is an example of the server components that are displayed Steps for upgrading the firmware To upgrade the firmware for components Steps for upgrading the firmware 137 ...

Страница 138: ...based on the Proposed Action and Severity Go to Status in Severity column Status in Proposed Action column Step 3 MANDATORY UPGRADE Step 3 is optional However it is recommended to perform step 3 for RECOMMENDED UPGRADE system stability and to avoid any known issues Step 4 MANDATORY NONE or DOWNGRADE Step 4 is optional However it is recommended to perform step 4 for RECOMMENDED NONE or DOWNGRADE sy...

Страница 139: ...ctive Fusion Manager by enter the following command ibrix_fm i b Perform a manual FM failover on the local node by entering the following command from the active Fusion Manager ibrix_fm m nofmfailover server1 The FM failover will take approximately one minute c If server1 is not the active Fusion Manager proceed to step e to fail over server1 to server2 d To see which node is now the active Fusion...

Страница 140: ...annot be moved from nofmfailover mode to active mode j Repeat steps a through h for the backup server component in this example switch server1 with server2 in the commands k Repeat steps a through I for each node that requires a firmware upgrade 6 If you are upgrading to 6 3 you must complete the steps provided in the After the upgrade section for your type of upgrade as shown in the following tab...

Страница 141: ...lManuals Adding new server blades on 9720 systems NOTE This requires the use of the Quick Restore DVD See Recovering the X9720 9730 Storage page 154 for more information 1 On the front of the blade chassis in the next available server blade bay remove the blank 2 Prepare the server blade for installation 3 Install the server blade Steps for upgrading the firmware 141 ...

Страница 142: ...il over For more information see the HP StoreAll Storage File System User Guide 6 Enable high availability automated failover by running the following command on server 1 ibrix_server m 7 Discover storage on the server blade ibrix_pv a 8 If you made any other customizations to other servers you may need to apply them to the newly installed server 142 Upgrading firmware ...

Страница 143: ...en the cluster is upgraded from a StoreAll software version earlier than 6 0 the support tickets collected using the ibrix_supportticket command will be deleted Before performing the upgrade download a copy of the archive files tgz from the admin platform diag supporttickets directory Collecting logs To collect logs and command results using the GUI 1 Select Cluster Configuration and then select D...

Страница 144: ...le When data is collected a compressed archive file is created and stored in a compressed archive file tgz under local ibrixcollect archive directory To download the collected data to your desktop select the collection and click Download from the Fusion Manager NOTE Only one collection can be downloaded at a time The average size of the archive file depends on the size of the logs present on indiv...

Страница 145: ...ill appear c Under General Settings enable or disable automatic collection by checking or unchecking the appropriate box d Enter the number of data sets to be retained in the cluster in the text box To enable disable automatic data collection using the CLI use the following command ibrix_collect C a Yes No To set the number of data sets to be retained in the cluster using the CLI use the following...

Страница 146: ...d format The file name of the script should strictly followed this format release Number _ add on_script_name sh When you provide the release number in the file name remove the period between the first and second digit of the version number For example assume you obtained the version number from the ibrix_version l command The output of the command displays the version number root host2 ibrix_vers...

Страница 147: ...ion will be included in the generated IbrixCollect tar file Output of the add on scripts is available only when the IbrixCollect process is completed and the tar files containing the output are extracted See Running an add on script page 147 and then Viewing the output from an add on script page 147 Running an add on script To run an add on script 1 Verify that the add on script is saved under the...

Страница 148: ...t host2 archive tar xvf host2_addOnCollection_2012 12 20 12 38 36 tgz In this instance host2_addOnCollection_2012 12 20 12 38 36 tgz is the individual node file hostname _ collection name _ time date stamp tgz 5 A directory with the host name is extracted The output of the add on script is found in the hostname logs add_on_script local ibrixcollect ibrix_collect_additional_data Find the directory ...

Страница 149: ...es under usr local ibrix ibrixcollect directory fm_summary xml Commands pertaining to the Fusion Manager node ss_summary xml Commands pertaining to the file serving node common_summary xml Commands and logs common to both Fusion Manager and file serving nodes NOTE These xml files should be modified carefully Any missing tags during modification might cause Ibrix Collect to not work properly Viewin...

Страница 150: ... storage subsystem for example replace failed Fibre Channel switches or replace a LUN that was removed from the storage array 2 Reboot the standby servers which will allow the failover to complete Cannot fail back because of a storage subsystem failure This issue is similar to the previous issue If a storage subsystem fails after you have initiated a failback the configuration database will record...

Страница 151: ... Services 2 Right click StoreAll client Services and select Properties 3 Change the startup type to Manual and then click OK 4 Debug the client problem When finished switch the Windows StoreAll client service back to automatic startup at boot time by repeating these steps and changing the startup type to Automatic Synchronizing information on file serving nodes and the configuration database To ma...

Страница 152: ...rom data that has been already backed up If the data needed has been backed up there is no automated way for Express Query to recover since that information has been deleted from the StoreAll file system after the backup It is however possible to replay the database logs from the backup Some data needed to rebuild the database is corrupted and therefore it cannot be used Even though database files...

Страница 153: ...mmand rm rf FS_MOUNTPOINT archiving database 3 Enable Express Query for the file system by entering the following command ibrix_fs T E f FSNAME NOTE The moment Express Query is enabled database repopulation starts for the file system specified by FSNAME 4 If there are any backup of the Custom Metadata with the tool MDExport re import them with MDImport as described in CLI Reference Guide NOTE If n...

Страница 154: ... screen appears enter qr to install the software Use a USB key 1 Copy the ISO to a Linux system 2 Insert a USB key into the Linux system 3 Execute cat proc partitions to find the USB device partition which is displayed as dev sdX For example cat proc partitions major minor blocks name 8 128 15633408 sdi 4 Execute the following dd command to make USB the QR installer dd if ISO file name with path o...

Страница 155: ...d cred selector chassis chassis oa cred type upwpair cred username Custom username cred password Custom password Command 3 opt hp platform bin hpsp_credmgmt update cred cred selector chassis chassis vc cred type upwpair cred username Custom username cred password Custom password Command 4 opt hp platform bin hpsp_credmgmt update cred cred selector chassis global ilo cred type upwpair cred username...

Страница 156: ...ng with the installation 9730 systems have been tested with specific firmware recipes Continuing the installation without upgrading to a supported firmware recipe can result in a defective system X9720 systems Manual configuration is required on the X9720 to recover the bond1 cluster network Click Cancel to leave the System Deployment Menu and follow the steps in Manually recovering bond1 as the c...

Страница 157: ...log box shows the configuration for this node Because you changed the hostname in the previous step the IP address is incorrect on the summary Select Reject and the following screen appears Select Enter FM IP 4 On the System Date and Time dialog box enter the system date day month year and time 24 hour format Tab to the Time Zone field and press Enter to display a list of time zones Select your ti...

Страница 158: ...e hyphen special character Do not use an underscore _ in the hostname The IP address is the address of the server on bond0 The default gateway provides a route between networks If your default gateway is on a different subnet than bond0 skip this field The Configuration Summary lists your configuration Select Ok to continue the installation 158 Recovering the X9720 9730 Storage ...

Страница 159: ...ly from blade 1 or you can enter the OA VC credentials manually The wizard now checks and verifies the following OA and VC firmware VC configuration hpspAdmin user accounts on the iLOs Chassis configuration The firmware on the SAS switches and notifies you if an update is needed The SAS configuration The storage firmware and notifies you if an update is needed Recovering an X9720 or 9730 file serv...

Страница 160: ...e interfaces configured on the system If the information is correct select Continue and go to the next step If the information specified for a bond is incorrect select the bond and then select Configure to customize the interface On the Select Interface Type dialog box select Bonded Interface On the Edit Bonded Interface dialog box enter the IP address and netmask specify any bond options and chan...

Страница 161: ...cluster page 165 for more information 9 The Configuration Summary dialog box lists the configuration you specified Select Commit to apply the configuration 10 Because the hostname you specified was previously registered with the management console the following message appears Select Yes to replace the existing server Recovering an X9720 or 9730 file serving node 161 ...

Страница 162: ...The restore process sets the root password to hpinvent the factory default 2 Verify information about the node you restored ibrix_server f p M N h SERVERNAME 3 Review vendor storage information Run the following command from the node hosting the active Fusion Manager ibrix_vs i The command reports status UUIDs firmware versions and other information for servers storage components drive enclosures ...

Страница 163: ...vices When you perform a Quick Restore of a file serving node the NFS SMB FTP and HTTP export information is not automatically restored to the node After operations are failed back to the node the I O from client systems to the node fails for the NFS SMB FTP and HTTP shares To avoid this situation manually restore the NFS SMB FTP and HTTP exports on the node before failing it back Restore SMB serv...

Страница 164: ...apply the settings to all servers This step resyncs the local user database 2 Run the following command ibrix_httpconfig R h HOSTNAME 3 Verify that HTTP services have been restored Use the GUI or CLI to identify a share served by the restored node and then browse to the share All Vhosts and HTTP shares should now be restored on the node Restore FTP services Complete the following steps 1 Take the ...

Страница 165: ...etwork scripts directory with the following parameters NOTE When creating the ifcfg bond1 file enter the cluster network IP address and mask for bond1 BOOTPROTO none BROADCAST 172 16 7 255 DEVICE bond1 IPADDR 172 16 3 16 NETMASK 255 255 248 0 ONBOOT yes SLAVE no USERCTL no BONDING_OPTS miimon 100 mode 1 updelay 100 NOTE In this step the MTU parameter is not displayed because it is optional 2 Make ...

Страница 166: ...ated at etc modprobe conf by entering the following commands alias bond0 bonding alias bond1 bonding 5 Set the host name and modify the etc hosts file a Run the following command to set the host name hostname r150b16 In this instance r150b16 is the host name b Edit the HOSTNAME parameter in the etc sysconfig network file with the host name value required for persistence HOSTNAME r150s16 c Add the ...

Страница 167: ...n r150b16 u bond0 x The following is the output iadconf xml does not exist creating new config wrote etc ibrix iadconf xml command successful c Restart the server by entering the following command NOTE If the chkconfig setting is set to off the StoreAll server will not restart after a reboot Change the chkconfig setting to on so that the StoreAll server will restart after a reboot chkconfig ibrix_...

Страница 168: ...ME IP ADDRESS r150b15 172 16 3 15 b Run the following command to install the passive Fusion Manager usr local ibrix sbin setupfm install P usr local ibrix C bond1 w 9009 M passive v 172 16 3 65 m 255 255 248 0 d bond1 0 Optional Run the following command to register Fusion Manager usr local ibrix sbin setupfm registerFM P usr local ibrix C bond1 v 172 16 3 65 w 9009 c If registered verify the regi...

Страница 169: ...keystrokes You need to use a local terminal when performing a recovery because networking has not yet been set up Occasionally when using the iLO integrated remote console the console will not respond to keystrokes To correct this situation remove and reseat the blade The iLO remote console will then respond properly Alternatively you can use a local KVM to perform the recovery The ibrix_auth comm...

Страница 170: ...stall administer and troubleshoot the HP X9700c To access these manuals go to the StoreAll Manuals page http www hp com support StoreAllManuals Using and maintaining file serving nodes HP ProLiant BL460c Server Blade Maintenance and Service Guide HP ProLiant BL460c Server Blade User Guide To access these manuals go to the Manuals page http www hp com support manuals and click bladesystem BladeSyst...

Страница 171: ...rts If you do not have the SKU number click the Hierarchy tab and navigate to your product to view a list of SKUs HP websites For additional information see the following HP websites http www hp com go X9000 http www hp com http www hp com go storage http www hp com support manuals http www hp com support downloads Rack stability Rack stability protects personnel and equipment WARNING To reduce th...

Страница 172: ...After registering you will receive email notification of product enhancements new driver versions firmware updates and other product resources 172 Support and other resources ...

Страница 173: ...cumentation that meets your needs To help us improve the documentation send any errors suggestions or comments to Documentation Feedback docsfeedback hp com Include the document title and part number version number or the URL when submitting your feedback 173 ...

Страница 174: ...ing each option by a comma for example o rw subtree_check 3 Complete steps 1 and 2 for every NFS export 4 Verify that all NFS exports have the subtree_check option set ibrix_exportfs l Upgrading the StoreAll software to the 6 1 release This section describes how to upgrade to the latest StoreAll software release The Fusion Manager and all file serving nodes must be upgraded to the new release at t...

Страница 175: ...ent I O continues during the upgrade The upgrade process takes approximately 45 minutes regardless of the number of nodes The total I O interruption per node IP is four minutes allowing for a failover time of two minutes and a failback time of two additional minutes Client I O having a timeout of more than two minutes is supported Preparing for the upgrade To prepare for the upgrade complete the f...

Страница 176: ...ervers have an earlier version of the iLO2 firmware download iLO2 version 2 05 using the following URL and copy the firmware update to each G6 server Follow the installation instructions noted in the URL This issue does not affect G7 servers http h20000 www2 hp com bizsupport TechSupport SoftwareDescription jsp lang en cc us prodTypeId 15351 prodSeriesId 1 146658 swItem MTX 949698a14e1 14478b9fe12...

Страница 177: ...ocesses 7 Unmount file systems on Linux StoreAll clients ibrix_umount f MOUNTPOINT 8 On all nodes hosting the passive Fusion Manager place the Fusion Manager into maintenance mode ibrixhome bin ibrix_fm m maintenance A 9 On the active Fusion Manager node disable automated failover on all file serving nodes ibrixhome bin ibrix_server m U 10 Run the following command to verify that automated failove...

Страница 178: ...pgrade is complete The upgrade script installs the Fusion Manager on all file serving nodes The Fusion Manager is in active mode on the node where the upgrade was run and is in passive mode on the other file serving nodes If the cluster includes a dedicated Management Server the Fusion Manager is installed in passive mode on that server 5 Upgrade Linux StoreAll clients See Upgrading Linux StoreAll...

Страница 179: ... a mismatch on your system you will see errors when connecting to ports 1234 and 9009 To correct this condition see Moving the Fusion Manager VIF to bond1 page 184 9 Because of a change in the inode format files used for snapshots must either be created on StoreAll 6 0 or later or the pre 6 0 file system containing the files must be upgraded for snapshots For more information about upgrading a fil...

Страница 180: ... to retrieve the current Active Directory settings 7 Mount file systems using the StoreAll Windows client GUI NOTE If you are using Remote Desktop to perform an upgrade you must log out and log back in to see the drive mounted Upgrading pre 6 0 file systems for software snapshots To support software snapshots the inode format was changed in the StoreAll 6 0 release The upgrade60 sh utility upgrade...

Страница 181: ...grating large files The upgrade60 sh utility does not upgrade files larger than 3 8 TB After the upgrade is complete and the file system is mounted migrate the file to another segment in the file system using the following command ibmigrate f filesystem m 1 d destination_segment file The following example migrates file 9 from its current segment to destination segment 2 ibmigrate f ibfs m 1 d 2 mn...

Страница 182: ...se the following command usr local ibrix autocfg bin ibrixapp upgrade f s If the install of the new image succeeds but the configuration restore fails and you need to revert the server to the previous install run the following command and then reboot the machine This step causes the server to boot from the old version the alternate partition usr local ibrix setup boot_info r If the public network ...

Страница 183: ...er node ib51 101 root ib51 102 ibrix_fm u ib51 101 Command succeeded 3 On the node hosting the active Fusion Manager register node ib51 101 and assign the correct IP address root ib51 102 ibrix_fm R ib51 101 I 10 10 51 101 Command succeeded NOTE When registering a Fusion Manager be sure the hostname specified with R matches the hostname of the server The ibrix_fm commands now show that node ib51 1...

Страница 184: ...conf xml In the file enter the new Agile_Cluster_VIF_IP address on the following line property name fusionManagerPrimaryAddress value xxx xxx xxx xxx 4 On the active Fusion Manager re register all backup management consoles using the bond1 Local Cluster IP address for each node ibrix_fm R management_console_name I local_cluster_network_IP NOTE When registering a Fusion Manager be sure the hostname...

Страница 185: ...ermine if your system was installed using the QR procedure run the df command If you see separate file systems mounted on local stage and alt your system was quick restored and you can use the automated upgrade procedure If you do not see these mount points proceed with the manual upgrade process Automatic upgrades This process uses separate partitioned space on the local disk to save node specifi...

Страница 186: ...nning 2 On the active management console node disable automated failover on all file serving nodes ibrixhome bin ibrix_server m U 3 Run the following command to verify that automated failover is off In the output the HA column should display off ibrixhome bin ibrix_server l 4 On the active management console node stop the NFS and SMB services on all file serving nodes to prevent NFS and SMB client...

Страница 187: ...sname m mountpoint 2 Remount all previously mounted StoreAll file systems on Windows StoreAll clients using the Windows client GUI 3 If automated failover was enabled before the upgrade turn it back on from the node hosting the active management console ibrixhome bin ibrix_server m 4 Confirm that automated failover is enabled ibrixhome bin ibrix_server l In the output HA should display on 5 From t...

Страница 188: ...erving node hosting the agile management console usr local ibrix autocfg bin ibrixapp upgrade f s If the install of the new image succeeds but the configuration restore fails and you need to revert the server to the previous install execute boot_info r and then reboot the machine This step causes the server to boot from the old version the alternate partition If the public network interface is dow...

Страница 189: ...cedure is run as an offline upgrade When each file serving node is upgraded all file systems are unmounted from the node and services are stopped Clients will experience a short interruption to file system access while the node is upgraded All file serving nodes and management consoles must be up when you perform the upgrade If a node or management console is not up the upgrade script will fail an...

Страница 190: ...ebooted if NFS or SMB causes the unmount operation to fail You can then perform the upgrade Clients will experience a short interruption to file system access while each file serving node is upgraded Standard upgrade for clusters with a dedicated Management Server machine or blade Use these procedures if your cluster has a dedicated Management Server machine or blade hosting the management console...

Страница 191: ...rogram For example if you expand the tarball in root the installer is in root ibrix 4 Change to the installer directory if necessary and execute the following command ibrixupgrade f The upgrade automatically stops services and restarts them when the process is complete 5 When the upgrade is complete verify that the StoreAll software services are running on the node etc init d ibrix_server status T...

Страница 192: ... management console must be upgraded first You can then upgrade file serving nodes in any order Preparing for the upgrade 1 From the management console disable automated failover on all file serving nodes ibrixhome bin ibrix_server m U 2 From the management console verify that automated failover is off In the output the HA column should display off ibrixhome bin ibrix_server l 3 Stop the NFS and S...

Страница 193: ...eAll installation on this node the installer is in root ibrix 2 Expand the distribution tarball or mount the distribution DVD in a directory of your choice Expanding the tarball creates a subdirectory named ibrix that contains the installer program For example if you expand the tarball in root the installer is in root ibrix 3 Change to the installer directory if necessary and execute the following...

Страница 194: ...er online or offline Future releases may require offline upgrades NOTE Be sure to read all instructions before starting the upgrade procedure Agile online upgrade Perform the agile online upgrade in the following order File serving node hosting the active management console File serving node hosting the passive management console Remaining file serving nodes and StoreAll clients Upgrading the file...

Страница 195: ...hat the agile management console is now Active on this node 10 On the node with the active agile management console move the installer_dir ibrix directory used in the previous release installation to ibrix old For example if you expanded the tarball in root during the previous StoreAll installation on this node the installer is in nl root ibrix 1 1 On the node with the active agile management cons...

Страница 196: ...installer directory if necessary and run the upgrade ibrixupgrade f The installer upgrades both the management console software and the file serving node software on the node 21 Verify the status of the management console etc init d ibrix_fusionmanager status The status command confirms whether the correct services are running Output will be similar to the following Fusion Manager Daemon pid 18748...

Страница 197: ... the ibrix and ipfs services are running lsmod grep ibrix ibrix 2323332 0 unused lsmod grep ipfs ipfs1 102592 0 unused If either grep command returns empty contact HP Support 7 From the management console verify that the new version of StoreAll software FS IAS has been installed on the file serving node ibrixhome bin ibrix_version l S 8 If the upgrade was successful failback the file serving node ...

Страница 198: ... stop ibrixhome bin ibrix_server s t nfs c stop Verify that all likewise services are down on all file serving nodes ps ef grep likewise Use kill 9 to kill any likewise services that are still running 4 Unmount all StoreAll file systems ibrixhome bin ibrix_umount f fsname Upgrading the file serving nodes hosting the management console Complete the following steps 1 On the node hosting the active m...

Страница 199: ...anagement console back to passive mode ibrixhome bin ibrix_fm m passive The node now resumes its normal backup operation for the active management console Upgrading remaining file serving nodes Complete the following steps on the remaining file serving nodes 1 Move the installer_dir ibrix directory used in the previous release installation to ibrix old For example if you expanded the tarball in ro...

Страница 200: ...de and then recheck the versions The installation is successful when all version indicators match If you followed all instructions and the version indicators do not match contact HP Support 6 Verify the health of the cluster ibrixhome bin ibrix_health l The output should show Passed on Troubleshooting upgrade issues Automatic upgrade fails Check the upgrade log file to determine the source of the ...

Страница 201: ... StoreAll 9730 CXs are numbered starting from the bottom for example the StoreAll 9730 CX 1 is located at the bottom of the rack StoreAll 9730 CX 2 is located directly above StoreAll 9730 CX 1 2 9730 CX 5 1 9730 CX 6 4 9730 CX 3 3 9730 CX 4 6 9730 CX 2 5 c7000 8 Onboard Administrator 2 7 9730 CX 1 10 Flex 10 VC module 2 9 6G SAS switch 4 12 1U Support shelf 1 1 TFT7600 Back view of the main rack 2...

Страница 202: ...Secondary I O module Drawer 2 4 Primary I O module Drawer 2 3 SAS port 1 connector 6 SAS port 1 connector 5 SAS port 2 connector 8 SAS port 2 connector 7 SAS port 1 connector 10 SAS port 1 connector 9 Primary I O module Drawer 1 12 Secondary I O module Drawer 1 1 1 SAS port 2 connector 202 StoreAll 9730 component and cabling diagrams ...

Страница 203: ... 2 to port 1 on the Bay 7 SAS switch SAS port 1 connector on the secondary I O module Drawer 2 to port 1 on the Bay 8 SAS switch TIP The number corresponding to the location of the 9730 CX corresponds to the port number on the SAS switch to which the 9730 CX is connected The ports on the SAS switches are labeled 1 through 8 starting from the left For example the 9730 CX 2 connects to port 2 on eac...

Страница 204: ...AS switch SAS port 1 connector on the secondary I O module Drawer 1 to port 2 on the Bay 6 SAS switch On Drawer 2 SAS port 1 connector on the primary I O module Drawer 2 to port 2 on the Bay 7 SAS switch SAS port 1 connector on the secondary I O module Drawer 2 to port 2 on the Bay 8 SAS switch 204 StoreAll 9730 component and cabling diagrams ...

Страница 205: ...switch SAS port 1 connector on the secondary I O module Drawer 1 to port 3 on the Bay 6 SAS switch On Drawer 2 SAS port 1 connector on the primary I O module Drawer 2 to port 3 on the Bay 7 SAS switch SAS port 1 connector on the secondary I O module Drawer 2 to port 3 on the Bay 8 SAS switch StoreAll 9730 CX 3 connections to the SAS switches 205 ...

Страница 206: ...the Bay 5 SAS switch SAS port 1 connector on the secondary I O module Drawer 1 to port 7 on the Bay 6 SAS switch On Drawer 2 SAS port 1 connector on the primary I O module Drawer 2 to port 7 on the Bay 7 SAS switch SAS port 1 connector on the secondary I O module Drawer 2 to port 7 on the Bay 8 SAS switch 206 StoreAll 9730 component and cabling diagrams ...

Страница 207: ...ore capacity blocks bringing the system to eight capacity blocks The servers are configured as file serving nodes with one of the servers hosting the active Fusion Manager The Fusion Manager is responsible for managing the file serving nodes The file serving nodes are responsible for managing segments of a file system Front view of a base cabinet 1 X9700c 1 2 TFT monitor and keyboard 3 c Class Bla...

Страница 208: ...of a base cabinet with one capacity block 1 Management switch 2 2 Management switch 1 3 X9700c 1 4 TFT monitor and keyboard 5 c Class Blade enclosure 6 X9700cx 1 208 The IBRIX X9720 component and cabling diagrams ...

Страница 209: ... view of a full base cabinet 6 X9700cx 3 1 X9700c 4 7 TFT monitor and keyboard 2 X9700c 3 8 c Class Blade Enclosure 3 X9700c 2 9 X9700cx 2 4 X9700c 1 10 X9700cx 1 5 X9700cx 4 Base and expansion cabinets 209 ...

Страница 210: ...700cx 4 1 Management switch 2 8 X9700cx 3 2 Management switch 1 9 TFT monitor and keyboard 3 X9700c 4 10 c Class Blade Enclosure 4 X9700c 3 1 1 X9700cx 2 5 X9700c 2 12 X9700cx 1 6 X9700c 1 210 The IBRIX X9720 component and cabling diagrams ...

Страница 211: ...abinet can contain from one to four capacity blocks The following diagram shows a front view of an expansion cabinet with four capacity blocks 5 X9700cx 8 1 X9700c 8 6 X9700cx 7 2 X9700c 7 7 X9700cx 6 3 X9700c 6 8 X9700cx 5 4 X9700c 5 Base and expansion cabinets 21 1 ...

Страница 212: ...The active Fusion Manager is responsible for managing the cluster configuration including file serving nodes and StoreAll clients The Fusion Manager is not involved in file system I O operations File serving nodes manage the individual segments of the file system Each segment is assigned to a specific file serving node and each node can own several segments Segment ownership can be migrated from o...

Страница 213: ...onnect bay 4 SAS Switch 10 Onboard Administrator 2 5 Interconnect bay 5 reserved for future use Flex 10 networks The server blades in the X9720 Storage have two built in Flex 10 10 NICs The Flex 10 technology comprises the Flex 10 NICs and the Flex 10 Virtual Connect modules in interconnect bays 1 and 2 of the performance chassis Each Flex 10 NIC is configured to represent four physical interfaces...

Страница 214: ...f redundancy and performance Capacity blocks A capacity block comprises an X9700c chassis containing 12 disk drives and an X9700cx JBOD enclosure containing 70 disk drives The X9700cx enclosure actually contains two JBODs one in each pull out drawer left and right drawer Each drawer contains 35 disk drives The serial number is the serial number of the X9700c chassis Every server is connected to ev...

Страница 215: ...ID 13 X9700c controller 1 5 Power LED 14 Fan 1 6 System fault LED 15 Power supply 1 7 On Off power button 8 Power supply 2 X9700cx dense JBOD with 70 disk drives NOTE This component is also known as the HP 600 Modular Disk System For an explanation of the LEDs and buttons on this component see the HP 600 Modular Disk System User Guide at http www hp com support manuals Under Storage click Disk Sto...

Страница 216: ...r 2 7 Secondary I O module drawer 2 3 Primary I O module drawer 1 8 Fan 4 Out SAS port Cabling diagrams Capacity block cabling Base and expansion cabinets A capacity block is comprised of the X9700c and X9700cx CAUTION Correct cabling of the capacity block is critical for proper IBRIX X9720 Storage operation 216 The IBRIX X9720 component and cabling diagrams ...

Страница 217: ...nk port Bay 5 reserved for future use 7 Management switch 2 1 Bay 6 reserved for future use 8 Management switch 1 2 Bay 7 reserved for optional components 9 Bay 1 Virtual Connect Flex 10 10 Ethernet Module for connection to site network 3 Bay 8 reserved for optional components 10 Bay 2 Virtual Connect Flex 10 10 Ethernet Module for connection to site network 4 Onboard Administrator 1 1 1 Bay 3 SAS...

Страница 218: ...gh 8 in interconnect bay 3 of the c Class Blade Enclosure Reserved for expansion cabinet use 6 SAS switch ports 1 through 4 in interconnect bay 4 of the c Class Blade Enclosure Ports 2 through 4 are reserved for additional capacity blocks 7 SAS switch ports 5 through 8 in interconnect bay 4 of the c Class Blade Enclosure Reserved for expansion cabinet use 8 SAS switch cabling Expansion cabinet NOT...

Страница 219: ...switch ports 5 through 8 in interconnect bay 3 of the c Class Blade Enclosure 6 X9700c 7 2 SAS switch ports 1 through 4 in interconnect bay 4 of the c Class Blade Enclosure 7 X9700c 6 3 SAS switch ports 5 through 8 in interconnect bay 4 of the c Class Blade Enclosure Used by base cabinet 8 X9700c 5 4 Cabling diagrams 219 ...

Страница 220: ...he skin Use heel straps toe straps or boot straps at standing workstations Wear the straps on both feet when standing on conductive floors or dissipating floor mats Use conductive field service tools Use a portable field service kit with a folding static dissipating work mat If you do not have any of the suggested equipment for proper grounding have an HP authorized reseller install the part NOTE ...

Страница 221: ...h these symbols indicates that the component exceeds the recommended weight for one individual to handle safely Weight warning WARNING The device can be very heavy To reduce the risk of personal injury or damage to equipment Remove all hot pluggable power supplies and modules to reduce the overall weight of the device before lifting Observe local health and safety requirements and guidelines for m...

Страница 222: ...ion over your facility wiring and installation requirements Device warnings and precautions WARNING To reduce the risk of electric shock or damage to the equipment Allow the product to cool before removing covers and touching internal components Do not disable the power cord grounding plug The grounding plug is an important safety feature Plug the power cord into a grounded earthed electrical outl...

Страница 223: ...l IBRIX X9720 Storage allow approximately 30 seconds between removing the failed component and installing the replacement This time is needed to ensure that configuration data about the removed component is cleared from the system registry To minimize airflow loss do not pause for more than a few minutes To prevent overheating due to an empty chassis bay use a blanking panel or leave the slightly ...

Страница 224: ...rial content declaration Обладнання відповідає вимогам Технічного регламенту щодо обмеження використання деяких небезпечних речовин в електричному та електронному обладнанні затвердженого постановою Кабінету Міністрів України від 3 грудня 2008 1057 Warranty information HP ProLiant and X86 Servers and Options http www hp com support ProLiantServers Warranties HP Enterprise Servers http www hp com s...

Страница 225: ... a bunch of disks KVM Keyboard video and mouse LUN Logical unit number A LUN results from mapping a logical unit number port ID and LDEV ID to a RAID group The size of the LUN is determined by the emulation mode of the LDEV and the number of LDEVs associated with the LUN MTU Maximum Transmission Unit NAS Network attached storage NFS Network file system The protocol used in most UNIX environments t...

Страница 226: ...SM SNMP User Security Model VACM SNMP View Access Control Model VC HP Virtual Connect VIF Virtual interface WINS Windows Internet Name Service WWN World Wide Name A unique identifier assigned to a Fibre Channel device WWNN World wide node name A globally unique 64 bit identifier assigned to each Fibre Channel node process WWPN World wide port name A unique 64 bit address used in a FC storage netwo...

Страница 227: ...2 configure SNMP trapsinks 73 define MIB views 74 delete SNMP configuration elements 75 enable or disable email notification 71 list email notification settings 72 list SNMP configuration 75 monitor 103 remove 104 types 70 view 103 exporting NFS 174 F failover automated 51 configure automated failover manually 62 crash capture 68 fail back a node 64 manual 64 NIC 50 server 55 troubleshooting 150 f...

Страница 228: ...ure 145 ibrix_reten_adm u command 181 IP address change for StoreAll client 132 L labels symbols on equipment 221 link state monitoring 52 Linux StoreAll clients upgrade 18 179 loading rack warning 221 localization 28 log files 106 collect for HP Support 143 logging in 28 M manpages 34 monitoring blade enclosures 88 chassis and components 87 cluster events 103 cluster health 104 file serving nodes...

Страница 229: ...hange IP address 132 identify a user network interface 130 monitor status 102 prefer a user network interface 131 start or stop processes 1 18 troubleshooting 150 tune 1 18 tune locally 122 user interface 34 view process status 1 18 StoreAll software shut down 1 15 start 1 17 upgrade 10 174 StoreAll software 5 5 upgrade 188 StoreAll software 5 6 upgrade 185 Subscriber s Choice HP 171 subtree_check...

Страница 230: ...terprise servers 224 HP Networking products 224 HP ProLiant and X86 Servers and Options 224 HP Storage products 224 websites HP 171 HP Subscriber s Choice for Business 171 spare parts 171 weight warning 221 Windows StoreAll clients upgrade 19 180 230 Index ...

Отзывы: