section
Service
Bus
interface
.
If
the
condition
persists
,
and
there
is
no
cable
connected
to
the
RF
lter
section
Service
Bus
interface
,
contact
your
HP
representative
.
(U)
RFFS
Error:
HARD
W
ARE
The
RF
lter
section
has
experienced
a
hardware
failure
.
If
the
condition
persists
after
presetting
the
instrument
or
cycling
power
,
contact
your
HP
representative
.
(H)
RFFS
Error:
TIMEOUT
Communication
failure
between
the
receiver
RF
section
and
the
RF
lter
section.
Check
power
to
the
RF
lter
section
and
check
that
the
A
UX
interface
cable
is
properly
connected
between
both
instruments
.
(U)
(H)
RFFS
Service
Bus
A
ctive
This
message
appears
in
the
active
function
area
of
the
receiver
RF
section
display
when
an
external
controller
communicates
with
the
RF
lter
section
via
the
RF
lter
section
Service
Bus
interface
.
(H)
RF
PRESEL
ERROR
F
or
an
HP
8546A/HP
85462A
only
.
Indicates
that
the
preselector
peak
routine
cannot
be
performed.
(H)
RF
PRESEL
TIMEOUT
F
or
an
HP
8546A/HP
85462A
only
.
Indicates
that
the
preselector
peak
routine
cannot
be
performed.
(H)
S
A
Limits
not
allowed
in
RCVR
mode
This
error
is
encountered
when
an
attempt
is
made
to
enable
limit-line
display
,
limit-margin
display
,
or
limit
testing
of
limits
dened
in
Signal
Analysis
mode
when
the
instrument
is
operating
in
Receiver
mode
.
T
o
correct
the
problem,
either
delete
the
limits
or
switch
to
Signal
Analysis
mode
.
(U)
S
AMPLE
F
AIL
Indicates
the
sample
detector
has
failed.
(H)
SIGNAL
CLIPPED
Indicates
that
the
current
FFT
measurement
sweep
resulted
in
a
trace
that
is
above
the
top
graticule
line
on
the
display
.
If
this
happens
,
the
input
trace
(trace
A)
has
been
\clipped,"
and
the
FFT
data
is
not
valid.
(U)
Signal
not
found
Indicates
the
PEAK
ZOOM
routine
did
not
nd
a
valid
signal.
(U)
Signals
do
not
t
expected
%
AM
pattern
Indicates
that
the
%
AM
routine
cannot
perform
the
percent
AM
measurement
because
the
onscreen
signals
do
not
have
the
characteristics
of
a
carrier
with
two
sidebands
.
(U)
Signals
do
not
t
expected
TOI
pattern
Indicates
that
the
TOI
routine
cannot
perform
the
third-order
intermodulation
measurement
because
the
onscreen
signals
do
not
have
the
characteristics
of
two
signals
and
two
distortion
products
.
(U)
SMPLR
UNLCK
Indicates
that
the
sampling
oscillator
circuitry
is
not
functioning
Error
Messages
13-11
Содержание 85422E
Страница 14: ...7 13 Using 3rd Ord Meas Function 7 19 12 1 External Keyboard Template 12 8 Contents 7 ...
Страница 61: ......
Страница 81: ......
Страница 116: ...Figure 6 25 Using Linearity Check to Identify Distortion Products Making EMI Diagnostic Measurements 6 35 ...
Страница 137: ......
Страница 161: ......
Страница 183: ......
Страница 195: ......
Страница 210: ...If nonrecoverable system errors occur regularly contact your HP representative Error Messages 13 15 ...
Страница 211: ......
Страница 218: ...Customer Support 14 7 ...
Страница 219: ......
Страница 229: ......