Menu
and
Softkey
Overview
The
keys
labeled
SETUP
,
FREQUENCY
,
and
MKR
are
all
examples
of
front-panel
keys
.
Pressing
most
front-panel
keys
access
menus
of
functions
that
are
displayed
along
the
right
side
of
the
display
screen.
These
menus
are
called
softkey
menus
.
Softkey
menus
list
functions
other
than
those
accessed
directly
by
the
front-panel
keys
.
T
o
activate
a
function
on
the
softkey
menu,
press
the
unlabeled
key
immediately
to
the
right
of
the
annotation
on
the
screen.
The
unlabeled
keys
next
to
the
annotation
on
the
display
screen
are
called
softkeys
.
Throughout
this
manual
front-panel
keys
are
indicated
by
a
box
around
the
key
label,
for
example
,
4
AMPLITUDE
5 ;
softkeys
are
indicated
by
shading
on
the
key
label,
for
example
,
NNNNNNNNNNNNNNNNNNNNNNN
REF
LVL
.
The
softkeys
displayed
depend
on
the
front-panel
key
pressed
and
which
menu
level
is
selected.
If
a
softkey
function's
value
can
be
changed,
it
is
called
an
active
function.
The
function
label
of
the
active
function
appears
on
the
display
in
inverse
video
.
F
or
example
,
if
you
press
4
AMPLITUDE
5
the
softkey
menu
of
related
amplitude
functions
is
displayed.
Note
the
function
labeled
NNNNNNNNNNNNNNNNNNNNNNN
REF
LVL
appears
in
inverse
video
.
The
message
\REF
LVL "
also
appears
in
the
active
function
block
on
the
display
,
indicating
it
is
the
active
amplitude
function
and
can
be
changed
using
any
of
the
data
controls
.
A
softkey
with
ON
and
OFF
in
its
label
can
be
used
to
turn
the
softkey's
function
on
or
o.
T
o
turn
the
function
on,
press
the
softkey
so
that
ON
is
underlined.
T
o
turn
the
function
o,
press
the
softkey
so
that
OFF
is
underlined.
An
ON
or
OFF
softkey
function
will
be
indicated
throughout
this
manual
as:
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
ANTENNA
ON
OFF
ON.
A
function
with
A
UTO
and
MAN
in
the
label
can
either
be
auto-coupled
or
have
its
value
manually
changed.
The
function's
value
can
be
changed
manually
by
pressing
the
softkey
until
MAN
is
underlined,
and
then
changing
its
value
with
the
numeric
keypad,
knob
,
or
step
keys
.
T
o
set
the
function
so
that
it
operates
automatically
,
press
the
softkey
so
that
A
UTO
is
underlined.
An
A
UTO
or
MAN
softkey
function
will
be
indicated
throughout
this
manual
as:
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
ATTEN
AUTO
MAN
A
UTO
.
When
some
softkeys
,
such
as
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
SCR
PWR
ON
OFF
and
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
SRC
ATN
MAN
AUTO
,
are
pressed
the
rst
time
,
only
the
function
will
be
highlighted.
T
o
change
the
value
of
the
function
use
the
numeric
keys
,
step
keys
or
knob
.
When
entering
a
value
with
the
numeric
keys
,
the
entry
must
be
terminated
by
pressing
one
of
the
units
keys
,
such
as
4
dB
5
or
4
dB V
5 .
When
adjusting
the
value
using
the
step
keys
or
knob
the
units
are
entered
automatically
by
the
receiver
.
When
you
are
nished
entering
or
adjusting
the
value
,
press
the
softkey
again
to
highlight
the
on
and
o
or
auto
and
manual
functions
.
A
summary
of
all
front-panel
keys
and
softkeys
can
be
found
in
Chapter
3,
\Key
Dictionary
Reference
,"
of
the
EMI
R
eceiver
Series
R
eference
manual.
1-12
Getting
Started
Содержание 85422E
Страница 14: ...7 13 Using 3rd Ord Meas Function 7 19 12 1 External Keyboard Template 12 8 Contents 7 ...
Страница 61: ......
Страница 81: ......
Страница 116: ...Figure 6 25 Using Linearity Check to Identify Distortion Products Making EMI Diagnostic Measurements 6 35 ...
Страница 137: ......
Страница 161: ......
Страница 183: ......
Страница 195: ......
Страница 210: ...If nonrecoverable system errors occur regularly contact your HP representative Error Messages 13 15 ...
Страница 211: ......
Страница 218: ...Customer Support 14 7 ...
Страница 219: ......
Страница 229: ......