Chapter 2 Command Summary
HP 53131A/132A Command Summary
2-34
Programming Guide
Table 2-2. HP 53131A/132A SCPI Command Summary (Continued)
Keyword/Syntax
Parameter Form
Std/
New
Comments
[:SENSe] (Cont.)
:FUNCtion
[:ON]
:PHASe
:ARM
[:STARt]
:SLOPe
:SOURce
:ROSCillator
:EXTernal
:CHECk
:FREQuency?
<sensor_function> (See below)
“[:][XNONe:]DCYCle [1] ”
“[:][XNONe:]PDUTycycle [1] ”
“[:][XNONe:]FALL:TIME [1] ”
“[:][XNONe:]FTIMe [1] ”
“[:][XNONe:]FREQuency [1 | 2 | 3] ”
“[:][XNONe:]FREQuency:RATio
[1,2 | 1,3 | 2,1 | 3,1] ”
“[:][XNONe:]NWIDth [1] ”
“[:][XNONe:]PERiod [1 | 2 | 3] ”
“[:][XNONe:]PHASe [1,2] ”
“[:][XNONe:]PWIDth [1] ”
“[:][XNONe:]RISE:TIME [1] ”
“[:][XNONe:]RTIMe [1] ”
“[:][XNONe:]TINTerval [1,2] ”
“[:][XNONe:]TOTalize [1] ”
“[:][XNONe:]VOLTage:MAXimum [1 | 2] ”
“[:][XNONe:]VOLTage:MINimum [1 | 2] ”
“[:]{XNONe:]VOLTage:PTPeak [1 | 2]
POSitive | NEGative
IMMediate | EXTernal
ON | OFF | ONCE
Std
Std
New
New
New
New
Std
Std
New
Std
Std
New
New
New
New
Std
Std
New
New
New
New
New
New
New
Std
Std
New
Std
Subtree. Selects the <sensor function> to
be sensed by the instrument.
Sets the <sensor function> to be sensed by
the instrument.
(Positive) duty cycle on channel 1.
(Positive) duty cycle on channel 1.
Fall Time on channel 1.
Fall Time on channel 1.
Frequency on channel 1, 2, or 3.
1
Frequency Ratio 1 to 2, 1 to 3, 2 to 1, or 3
to 1.
Negative Pulse Width on channel 1.
Period on channel 1, 2, or 3.
Phase of channel 1 relative to channel 2.
Positive Pulse Width on channel 1.
Rise Time on channel 1.
Rise Time on channel 1.
Time Interval channel 1 to channel 2.
Totalize on channel 1.
Voltage Maximum on channel 1 or 2.
Voltage Minimum on channel 1 or 2.
Voltage Peak to Peak on Channel 1 or 2.
Subtree. Controls the phase measuring
capabilities of the instrument.
Subtree.
Subtree. Synchronizes Phase start arm with
events.
Sets the slope of the external start arm
signal used in external arming phase
measurements. Only applies when
[:SENS]:PHAS:ARM[:STAR]:SOUR EXT is
selected.
Sets the start arm for phase
measurements.
Subtree. Controls the Reference
OSCillator.
Subtree.
Set the enable for checking the validity and
presence of the external reference.
Query only. Returns the frequency value of
the external reference oscillator.
______________________________
1
For HP 53131A firmware revision s below 3335, only Ratio 1 to 2 and Ratio 1 to 3 were offered.
Содержание 53131A
Страница 1: ...Programming Guide HP 53131A 132A 225 MHz Universal Counter ...
Страница 2: ......
Страница 13: ...1 1 Before You Start ...
Страница 24: ...Chapter 1 Before You Start Related Documentation 1 12 Programming Guide ...
Страница 25: ...2 2 Command Summary A Quick Reference ...
Страница 68: ...Chapter 2 Command Summary RST Response 2 44 Programming Guide ...
Страница 69: ...3 3 Programming Your Universal Counter for Remote Operation ...
Страница 167: ...4 4 Command Reference A Dictionary ...
Страница 172: ...Chapter 4 Command Reference CALCulate Subsystems 4 6 Programming Guide Figure 4 1 The CALCulate Subsystems ...
Страница 310: ...Chapter 4 Command Reference WAI Wait to Continue Command 4 144 Programming Guide ...
Страница 311: ...5 5 Errors ...
Страница 329: ......
Страница 330: ...H Manual Part Number 53131 90044 Printed in U S A NOVEMBER 1996 ...