Table 2-2. HP 53131A/132A SCPI Command Summary
Keyword/Syntax
Parameter Form
Std/
New
Comments
:ABORt
Std
Event; no query. Aborts measurement in progress.
:CALCulate[1]
:DATA?
:FEED
:IMMediate
:AUTO
:MATH
[:EXPRession]
:CATalog?
[:DEFine]?
:NAME | :SELect
:STATe
“[:]SENSe[1]”
<Boolean>
SCALE_OFFSET
<Boolean>
Std
Std
Std
Std
Std
Std
Std
New
New
New
Std
Subsystem. Performs post-acquisition math processing
(scale and offset) and data transfer on the data
acquired by a SENSe function.
Query only. Returns scaled/offset measurement result.
Sets the data flow to be fed into the CALCulate block.
Event or query; causes the Counter to recalculate
existing data without re-acquiring.
Enables/disables automatic post-processing.
Subtree.
Subtree.
Returns the name of the defined equation,
SCALE_OFFSET.
Returns the expression (equation) used for
math (scale/offset) processing.
Sets the name of selected math expression (equation).
Enables/disables math (scale/offset) processing.
Note that this setting must be enabled for any of the
other :CALC[1] settings to be used.
:CALCulate2
:FEED
:IMMediate
:AUTO
:LIMit
:CLEar
:AUTO
[:IMMediate]
:DISPlay
:FAIL?
“[:]CALCulate[1] ”
<Boolean>
<Boolean>
GRAPh | NUMBer
Std
Std
Std
Std
Std
Std
Std
Std
New
Std
Subsystem. Performs post-acquisition LIMit testing and
data transfer.
Sets the data flow to be fed into the CALCulate2 block.
Event; no query. Causes the Counter to recalculate
existing data without re-acquiring.
Enables/disables automatic post-processing.
Subtree. Collects together the commands associated
with controlling and getting reports from a single LIMit
test.
Subtree.
Enables the automatic clearing of limit test results.
Event; no query. Clears the limit test results.
Sets whether the measurement display is numeric or
symbolic (on a graph).
Query only. Returns a 0 or 1 to indicate if the last
tested measurement passed or failed the limit test.
0 = pass; 1 = fail.
Содержание 53131A
Страница 1: ...Programming Guide HP 53131A 132A 225 MHz Universal Counter ...
Страница 2: ......
Страница 13: ...1 1 Before You Start ...
Страница 24: ...Chapter 1 Before You Start Related Documentation 1 12 Programming Guide ...
Страница 25: ...2 2 Command Summary A Quick Reference ...
Страница 68: ...Chapter 2 Command Summary RST Response 2 44 Programming Guide ...
Страница 69: ...3 3 Programming Your Universal Counter for Remote Operation ...
Страница 167: ...4 4 Command Reference A Dictionary ...
Страница 172: ...Chapter 4 Command Reference CALCulate Subsystems 4 6 Programming Guide Figure 4 1 The CALCulate Subsystems ...
Страница 310: ...Chapter 4 Command Reference WAI Wait to Continue Command 4 144 Programming Guide ...
Страница 311: ...5 5 Errors ...
Страница 329: ......
Страница 330: ...H Manual Part Number 53131 90044 Printed in U S A NOVEMBER 1996 ...