Type
(720)
(850)
(1000)
(1150)
H (720)
H (1000)
• Nominal heat output at 80/60 °C, natural gas
kW
127-665
148-788
199-927 208-1060 127-665
199-927
• Nominal heat output at 40/30 °C, natural gas
kW
142-720
166-850 224-1000 233-1150 142-720 224-1000
• Nominal heat output at 80/60 °C, propane
2
kW
169-655
235-789
269-927
-
169-655
269-927
• Nominal heat output at 40/30 °C, propane
2
kW
185-720
257-851 293-1000
-
185-720 293-1000
• Nominal load with natural gas
1
kW
130-677
152-802
205-943 214-1080 130-677
205-943
• Nominal load with propane
2
kW
175-677
238-803
272-943
-
175-677
272-943
• Working pressure heating maximum/minimum
bar
6.0/1.0
6.0/1.0
6.0/1.0
6.0/1.0
8.0/1.0
8.0/1.0
• Test pressure
bar
9.0
9.0
9.0
9.0
12.0
12.0
• Working temperature maximum
°C
90
90
90
90
90
90
• Boiler water content
l
478
860
793
737
478
793
•
Minimum water flow
l/h
0
0
0
0
0
0
• Boiler weight (without water content. incl. casing)
kg
1396
1850
1965
2023
1424
1962
•
Boiler efficiency at 80/60 °C in full-load operation (related to net cal
-
orific value NCV/gross calorific value GCV)
%
98.3/88.6 98.3/88.6 98.3/88.6 98.3/88.6 98.3/88.6 98.3/88.6
•
Boiler efficiency at 30 % partial load (EN 15502) (related to net calo
-
rific value NCV/gross calorific value GCV)
%
108.0/97.3 108.1/97.4 108.1/97.4 108.1/97.4 107.7/97.0 108.1/97.4
•
Standard efficiency
(DIN 4702-8)
40/30 °C %
109.9/99.0 109.9/99.0 109.9/99.0 109.9/99.0 109.9/99.0 109.9/99.0
(related to net calorific value NCV/gross calorific value GCV)
75/60 °C %
107.4/96.8 107.4/96.8 107.4/96.8 107.4/96.8 107.4/96.8 107.4/96.8
• Heat loss rate at 70 °C
Watt
1000
1200
1200
1200
1000
1200
• NOx class (EN 15502)
6
6
6
6
6
6
• Standard emission rate
Nitrogen oxides
mg/kWh
48
35
35
38
48
35
• Content of CO
2
in the flue gas maximum/minimum output
%
9.0/8.8
9.0/8.8
9.0/8.8
9.0/8.8
9.0/8.8
9.0/8.8
• Dimensions
see table of dimensions
• Connections
Flow/return
DN
DN125/
PN6
DN125/
PN6
DN125/
PN6
DN125/
PN6
DN125/
PN16
DN125/
PN16
Gas
inches
Rp 2″
Rp 2″
Rp 2″
Rp 2″
Rp 2″
Rp 2″
Flue gas Ø inside
mm
302
402
402
402
302
402
•
Gas flow pressure
minimum/maximum
Natural gas E/LL
mbar
17.4-80
15-
3
0
15-30
15-
3
0
17.4-80
1
5-30
Propane
mbar
37-57
37-57
37-57
-
37-57
37-57
• Gas connection value at 15 °C/1013 mbar:
Natural gas E (Wo = 15.0 kWh/m
3
) NCV = 9.97 h/m
3
m
3
/h
67.7
80.2
94.3
108.2
67.7
94.3
Natural gas LL (Wo = 12.4 kWh/m
3
) NCV = 8.57 h/m
3
m
3
/h
79.0
93.6
110.0
126.2
79.0
110.0
Propane
3
(NCV = 25.9 kWh/m
3
)
m
3
/h
26.1
31.0
36.4
-
26.1
36.4
• Operation voltage
V/Hz
230/50
230/50
1x230/50
3x400/50
1x230/50
3x400/50
230/50
1x230/50
3x400/50
• Control voltage
V/Hz
24/50
24/50
24/50
24/50
24/50
24/50
• Electrical power consumption min./max.
Watt
62/1150
51/1010 103/2420 103/2730 62/1150 103/2420
• Stand-by
Watt
9
9
9
9
9
9
• IP rating (integral protection)
IP
20
20
20
20
20
20
• Lowest ambient temperature during operation
°C
5
5
5
5
5
5
• Highest ambient temperature during operation
°C
40
40
40
40
40
40
• Sound power level
- Heating noise (EN 15036 part 1) (room air dependent)
dB(A)
77
77
82
83
77
82
- Exhaust noise is radiated from the mouth (DIN 45635 part 47)
dB(A)
74
70
74
80
74
74
• Sound pressure level heating noise (depending on installation con-
ditions)
3
dB(A)
67
67
72
73
67
72
• Condensate quantity (natural gas ) at 40/30 °C
l/h
63.6
75.4
88.9
102.2
63.6
88.9
• pH value of the condensate
approx.
4.2 approx.
4.2 approx.
4.2 approx.
4.2 approx.
4.2 approx.
4.2
• Flue gas system: requirements. values
Temperature class
T120
T120
T120
T120
T120
T120
Type of connection
B23P, C53
Flue gas mass flow at nominal heat load
kg/h
1124
1331
1565
1800
1124
1565
Flue gas mass flow at lowest nominal heat load
kg/h
195
230
311
322
195
311
Flue gas temperature at nominal output
and operation
80/60 °C
°C
71
69
69
71
71
69
Flue gas temperature at nominal output
and operation
40/30 °C
°C
46
49
49
50
46
49
Flue gas temperature at lowest nominal heat load and operation 40/30 °C °C
32
32
32
32
32
32
Volume flow rate combustion air
Nm
3
/h
838
992
1167
1342
838
1167
Feed pressure
total at the combustion air/flue gas line
4
Pa
130
130
130
130
130
130
Maximum draught/depression at flue gas outlet
Pa
-50
-50
-50
-50
-50
-50
19
1
Data related to NCV.
The boiler series is tested for EE/H-settings. With a factory setting of the Wobbe coefficient
of 15.0 kWh/m
3
operation at a Wobbe coefficient of 12.0 up to 15.7 kWh/m
3
is possible without new settings.
2
Data related to NCV.
3
See also notes at “Engineering”.
4
Details for multi-boiler plants (cascade) with common flue gas line: see Hoval UltraGas
®
(250D-2000D).
4 217 215 / 00
UK
TECHNICAL INFORMATION
Содержание UltraGas 1000
Страница 57: ...57 4 217 215 00...