GPS - NTP Time Server with LAN Interface 8029NTS-V2/GPS - V08.00
105 / 121
hopf
Elektronik GmbH
Nottebohmstr. 41
• D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: [email protected]
11.4 Power Supplies
AC Wide-Range Power Supplies
Internal Power Supply
(Only wide input range)
hopf
Type:
AC-M05-D
hopf
Type:
AC-M10-D
Input Data
Nominal input voltage
100-240V AC
110-250V DC
(wide input range)
100-240V AC
110-250V DC
(wide input range)
Input voltage range
85-264V AC 110-370V
DC
85-264V AC 110-370V
DC
Frequency
47-440Hz 0 Hz
47-440Hz 0 Hz
Current consumption (at nominal
values)
approx. 0.15A (120V AC)
0.10A (230V AC)
approx. 0.30A (120V AC)
0.20A (230V AC)
Inrush current
typ. 15A (I
O
= 100%) 120V
AC
typ. 30A (I
O
= 100%) 230V
AC
typ. 15A (I
O
= 100%) 120V
AC
typ. 30A (I
O
= 100%) 230V
AC
Hold-up time at nominal laod
> 20msec. (> 100V AC)
> 20msec. (> 100V AC)
Start-up time after connected
mains voltage
< 1 sec.
< 1 sec.
Transient overvoltage protection
Overvoltage protection III
(EN 60664-1)
Overvoltage protection III
(EN 60664-1)
Protection supply, internal
400 mA slow blow (device
protection)
400 mA slow blow (device
protection)
Recommended back-up fuse (AC)
Circuit breaker 6A, 10A
charakteristics B (EN 60898)
Circuit breaker 6A, 10A
charakteristics B (EN 60898)
Leakage current against PE
< 0.5mA (60Hz, according to
EN 60950)
< 0.5mA (60Hz, according to
EN 60950)
Input isolation voltage / PE
2000V AC, 1 minute,
leakage current = 10mA,
500V DC, 50MOhm min.
(at room temperature)
2000V AC, 1 minute,
leakage current = 10mA,
500V DC, 50MOhm min.
(at room temperature)
Output Data (only internal)
Internal nominal output voltage
5V DC
5V DC
Nominl output current
I
N
0° C ... +55° C
1A (U
OUT
= 5V DC)
2A (U
OUT
= 5V DC)
Efficiency
> 77% (at 230V AC
and nominal values)
> 74% (ati 230V AC
and nominal values)
Function Display (Power LED)
LED green