GPS - NTP Time Server with LAN Interface 8029NTS-V2/GPS - V08.00
53 / 121
hopf
Elektronik GmbH
Nottebohmstr. 41
• D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: [email protected]
7.3.2.5.2 SINEC H1 time datagram (Activation Key necessary)
Configuration of the SINEC H1 time datagram
Broadcast transmission intervals of the SINEC H1 time datagram (Send Interval):
•
every second
•
every 10 second
•
every 60 second
Timebase see also Chapter 13.2.1 Time-specific expressions:
•
Local time
•
UTC
•
Standard time
•
Standard time with daylight / standard time status
Destination MAC Address:
•
09:00:06:03:FF:EF
•
09:00:06:01:FF:EF
•
FF:FF:FF:FF:FF:FF
Synchronization Status based on Starting Transmission (Minimum Accuracy)
This setting defines at which internal accuracy status the SINEC H1 time datagram should be
transmitted (see
Chapter 13.5 Accuracy & NTP Basic Principles
Chapter 11 Technical
):
•
LOW
•
MEDIUM
•
HIGH
The setting Minimum Accuracy = LOW may lead to the output of non-
synchronised (thus possibly wrong) time information.