I
NSTALLATION
22 / 121
GPS - NTP Time Server with LAN Interface 8029NTS-V2/GPS - V08.00
hopf
Elektronik GmbH
Nottebohmstr. 41
• D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: [email protected]
5
Installation
The installation of the Time Server 8029NTS/GPS is described below.
5.1
Installation/Dismounting of the DIN Rail Housing
The Time Server 8029NTS/GPS can be mounted on all rails in accordance with DIN EN 60715
TH35 and is designed for horizontal mounting.
Dimensions
The dimensions of the housing can be found in
Chapter 11.5 Dimensions
•
Time Server 8029NNTS/GPS
–
Housing: TYPE 2
In order to guarantee an adequate convection, we recommend the
following minimum distance from other modules:
•
5.0 cm in vertical direction and
•
1.0 cm in horizontal direction.
5.1.1 Mounting
Place
the module’s rail guide bar against the lower edge of the rail, push the module
upwards, and clip to the back.
5.1.2 Dismounting
Push the module upwards and then tip forward to remove from the rail.