![hopf 8029NTS-V2/GPS Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/hopf/8029nts-v2-gps/8029nts-v2-gps_technical-manual_2161869019.webp)
S
YSTEM
B
EHAVIOUR
GPS - NTP Time Server with LAN Interface 8029NTS-V2/GPS - V08.00
19 / 121
hopf
Elektronik GmbH
Nottebohmstr. 41
• D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: [email protected]
4.4
Firmware Update
The Time Server 8029NTS/GPS is a multi processor system. For this reason a firmware
update always consists of a so called Software SET including up to three (3) program releases
defined by the SET version needed to be loaded into the board.
ATTENTION
In order to select the correct image update, Chapter 7.3.5.5.1 Select
Image Update must be checked!
An update is a critical process.
The device should not be turned off during the update and the network
connection to the device not be interrupted.
All programs of a SET needed to be uploaded to ensure a defined
operation condition.
The progam releases assigned to a SET version may be taken from the
release notes of the software SETs of the Time Sever 8029NTS/GPS.
4.4.1 Firmware Update 8029NTS (WebGUI: Device)
The general process of a software update of Module 8029NTS is described below:
For selection of the correct update set the identifier
8029NTS-V2
has to be
observed obligatory. The extension V2 describes a hardware version of
8029NTS.
8029NTS-V2 can be recognized:
•
By the imprint stated on the front panel "
hopf
8024GPS / 8029NTS
"
•
By the label on the housing cover "
8029NTS-V2
"
•
In WebGUI at the Web-banner "
8029NTS-V2
"
The firmware update 8029NTS-V2 has to be performed as a SET.
The software package contained in the ZIP archive has to be unpacked. The following steps
have to be executed in the following sequence:
1. Image Update 8029NTS-V2
2. H8 Firmware Update 8029NTS-V2 (optional)
3. H8 Firmware Update 8024GPS