COM0
/
COM1
S
ERIAL
I
NTERFACES
System 6844(RC) - V03.00
97 / 157
hopf
Elektronik GmbH
Nottebohmstr. 41
• D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: [email protected]
6.3.4.3 Status
b3 b2 b1 b0
Meaning
Status:
x
x
x
0
no announcement hour
x
x
x
1
announcement (DST changeover)
x
x
0
x
standard time
x
x
1
x
daylight saving time (DST)
x
0
x
x
no announcement leap second
x
1
x
x
announcement leap second
0
x
x
x
crystal operation
1
x
x
x
radio operation
Day of the Week:
0
0
0
1
Monday
0
0
1
0
Tuesday
0
0
1
1
Wednesday
0
1
0
0
Thursday
0
1
0
1
Friday
0
1
1
0
Saturday
0
1
1
1
Sunday
Status
Operating Mode
Time
DST changeover
Leap Second
0 = 0000
quartz
standard time
no announcement
no announcement
1 = 0001
quartz
standard time
announcement
no announcement
2 = 0010
quartz
DST
no announcement
no announcement
3 = 0011
quartz
DST
announcement
no announcement
4 = 0100
quartz
standard time
no announcement
announcement
5 = 0101
quartz
standard time
announcement
announcement
6 = 0110
quartz
DST
no announcement
announcement
7 = 0111
quartz
DST
announcement
announcement
8 = 1000
radio
standard time
no announcement
no announcement
9 = 1001
radio
standard time
announcement
no announcement
A = 1010
radio
DST
no announcement
no announcement
B = 1011
radio
DST
announcement
no announcement
C = 1100
radio
standard time
no announcement
announcement
D = 1101
radio
standard time
announcement
announcement
E = 1110
radio
DST
no announcement
announcement
F = 1111
radio
DST
announcement
announcement
DST = daylight saving time
6.3.4.4 Example
(STX)841234561807028230(LF)(CR)(ETX)
It is Thursday 18.07.2002 - 12:34:56 o'clock
radio operation
standard time
no announcement of a changeover
The difference time to UTC is +2.30 h