COM0
/
COM1
S
ERIAL
I
NTERFACES
102 / 157
System 6844(RC) - V03.00
hopf
Elektronik GmbH
Nottebohmstr. 41
• D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: [email protected]
6.3.7.3 Status
The 14
th
character ("Quality Identifier") informs about the synchronisation status of the clock.
Possible values and their meaning are listed below.
"?"
=
question mark =
no radio controlled time
"
_
" =
space
=
radio controlled time at hand
"A" =
Hex 41
=
crystal operation for more than 20 minutes
"B"
=
Hex 42
=
crystal operation for more than 41 minutes
"C"
=
Hex 43
=
crystal operation for more than 416 minutes
"X" =
Hex 58
=
crystal operation for more than 4160 minutes
6.3.7.4 Example
(SOH)050:12:34:56 _ (CR) (LF)
( _ ) = Space
It is 12:34:56 o'clock
radio operation
50th day of the year