S
YSTEM
P
ARAMETERIZATION AND
O
PERATION
68 / 157
System 6844(RC) - V03.00
hopf
Elektronik GmbH
Nottebohmstr. 41
• D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: [email protected]
5.3.7 Serial Interface Parameters
With this menu the serial interface parameters can be shown.
5.3.7.1 Display Frames for the COM0 Serial Interface Parameters
The configuration of the COM0 interface is shown with these display frames. The signifi-
cance of the configuration can be found in
Chapter 6 COM0 / COM1 Serial Interfaces
COM 0 Interface Parameter Displays
Selection frame:
S H O W C O M 0 S E R I A L
P A R A M E T E R Y / N
Display frame:
B d : 0 9 6 0 0 W : 8
P : N S : 1
Mode Byte 1 Displays
Selection frame:
S H O W C O M 0
M O D E B Y T E _ 1 Y / N
Display frame:
M o d B _ 1 7 6 5 4 3 2 1 0
C O M 0 > 1 1 0 0 0 0 0 0
Mode Byte 2 Displays
Selection frame:
S H O W C O M 0
M O D E B Y T E _ 2 Y / N
Display frame:
M o d B _ 2 7 6 5 4 3 2 1 0
C O M 0 > 0 0 0 0 1 1 0 0
Depending on the selected string,
Mode Byte 3
is also available in the
menu for the required configuration of the string.
Mode Byte 3 Displays
Selection frame:
S H O W C O M 0
M O D E B Y T E _ 3 Y / N
Display frame:
M o d B _ 3 7 6 5 4 3 2 1 0
C O M 0 > 0 0 0 0 0 0 0 1
5.3.7.2 Display Frames for the COM1 Serial Interface Parameters
The configuration of the COM1 interface is shown with these display frames. The display
functions are analogue to the COM0 interface display.
The parameter settings have no effect on the serial interface COM1 in case
of synchronisation of System via serial interface by the
hopf
Master/Slave
string. At this, the parameters are firmly adjusted to 9600baud, 8 data bit, no
parity an stop bit.