T
ECHNICAL
D
ATA
148 / 157
System 6844(RC) - V03.00
hopf
Elektronik GmbH
Nottebohmstr. 41
• D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: [email protected]
11.2 Specific Technical Data for 1U
Technical Data - System 6844(RC) 1U
Housing construction:
Sheet steel / aluminium, closed
Housing measurement:
see
Chapter 1.2.3.1 19 Inch Rack 1U/84HP
Housing protection class:
IP20
Protection class:
I, with PE connection.
Additional earth screw for cables up to 16mm
2
Cooling:
Active cooling by fans, temperature-controlled.
Air inlets left / right
Weight:
approx. 3kg
AC Power Supply
(with wide input range)
Nominal input voltage:
100-240V AC / 47-63Hz
Connection via input connector compliant
with IEC/EN 60320-1/C14 with EMI line filter
and switch
Input voltage range:
85-264V AC
Frequency:
47-63Hz
Current consumption (at nominal values):
ca. 0.37A (120V AC) / 0.23A (230V AC)
Starting current:
typ. 15A (I
O
= 100%) 120V AC
typ. 30A (I
O
= 100%) 230V AC
Mains failure bridging
at nominal load:
> 20msec. (> 100V AC)
Turn-on time after application of mains
voltage:
< 500msec.
Transient overvoltage protection:
Overvoltage category II (EN 60664-1)
Input fuse - internal:
2A (equipment protection)
Recommended pre-fuse:
Line protection switch 6A, 10A
characteristic B (EN 60898)
PE leakage current:
< 0.75mA (60Hz, compliant with EN 60950)
Insulation voltage input / PE:
2000V AC,
1 minute, residual current = 10mA,
500V DC, 50M
at least (at room temperature)
Output Data (internal only)
Internal nominal output voltage:
5V DC
Nominal output current I
N
0°C .. +55°C:
6A
(U
OUT
= 5V DC)
Efficiency:
> 74%
(at 230V AC and nominal values)
Function display (Power LED):
LED green
DC Power Supply (Option)
Nominal input voltage:
24V DC
48V DC
110/220V DC
Input voltage range:
18-36V DC
36-76V DC
100-250V DC
Current consumption (at
nominal values):
1.36A
0.68A
0.40A
Turn-on time after applica-
tion of mains voltage:
< 200msec.
< 200msec.
< 500msec.
Input fuse - internal
(equipment protection):
4A fast-acting
2A fast-acting
2A
Insulation voltage
input / output:
1.500V DC
1 minute,
500V DC 50M
at
least (20°C
15°C)
1.500V DC
1 minute,
500V DC 50M
at
least (20°C
15°C)
2000V AC,
1 Minute, residual current
= 10mA, 500V DC, 50M