COM0
/
COM1
S
ERIAL
I
NTERFACES
92 / 157
System 6844(RC) - V03.00
hopf
Elektronik GmbH
Nottebohmstr. 41
• D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: [email protected]
Day of the Week:
0
x
x
x
CEST / CET
1
x
x
x
UTC - time
x
0
0
1
Monday
x
0
1
0
Tuesday
x
0
1
1
Wednesday
x
1
0
0
Thursday
x
1
0
1
Friday
x
1
1
0
Saturday
x
1
1
1
Sunday
Status
operation mode
time
announcement SZ-WZ-SZ
0 = 0000
time invalid
winter
no announcement
1 = 0001
time invalid
winter
announcement
2 = 0010
time invalid
summer
no announcement
3 = 0011
time invalid
summer
announcement
4 = 0100
quartz
winter
no announcement
5 = 0101
quartz
winter
announcement
6 = 0110
quartz
summer
no announcement
7 = 0111
quartz
summer
announcement
8 = 1000
radio
winter
no announcement
9 = 1001
radio
winter
announcement
A = 1010
radio
summer
no announcement
B = 1011
radio
summer
announcement
C = 1100
radio
winter
no announcement
D = 1101
radio
winter
announcement
E = 1110
radio
summer
no announcement
F = 1111
radio
summer
announcement
6.3.2.4 Example
(STX)E4123456180702(LF)(CR)(ETX)
It is Thursday 18.07.2002 - 12:34:56 o'clock.
radio operation (high accuracy)
daylight saving time
no announcement of a changeover
( ) - ASCII-control characters e.g. (STX)