6.1.2.11 Mode Byte 3 / Bit7-Bit0
The configuration of Mode Byte 3 is dependent on the preset data string. Explanations about
this are given in the relevant chapter concerning the data string.
6.1.3 Serial Data String Request
Serial data string requests that are not included in this Chapter are described under Data
Strings.
6.1.3.1 Serial Requests with ASCII Characters (
hopf
Standard and
hopf
2000)
The transmission of a data string can also be triggered by the user on enquiry by means of
an ASCII character. The following characters trigger the transmission of the standard string:
ASCII
"D"
- for Time / Date (Local Time)
ASCII
"G"
- for Time / Date (UTC Time)
The System answers within 1msec. with the corresponding data string.
Since this is often too fast for the requesting computer, it is also possible to realize a re-
sponse delay in 10msec. steps on request via software. For the delayed transmission of the
data string, the requesting computer transmits the lower case letters "
d
,
g
" to the clock with a
two position multiplication factor.
The clock interprets the multiplication factor as a hexadecimal value.
Example:
The computer transmits
ASCII gFF
(Hex 67, 46, 46)
The clock transmits the Time / Date (UTC Time) data string after approx. 2550 milliseconds.