7.1.6 RC-Pulse IMP 1-4 - One Time / Variable Pulse per Weekday
This mode generates a single pulse per time and weekday or cyclic pulses at a variable, ad-
justable date per time and day of the week.
This is the appropriate input field for setting the different values for hour, minute and second
of the pulse duration and weekday by entering or selecting a plausible value.
A configuration of the pulse duration by plausible values results in an accurate output to the
second at the appropriate time with the adjusted pulse length.
Individual values to disable the pulse width for the activation of variable pulses according to
the desired pulse output have to be deactivated. These values to calculate the pulse time
points are ignored.
This allows the configuration of one pulse output within a certain time and weekday range.
The pulse lengths can be adjusted in the range of
1 - 65,500 msec
.
The signal output can be inverted.
Examples:
Single pulse per weekday
hour
m
in
u
te
s
e
c
o
n
d
d
a
y
o
f
th
e
wee
k
p
u
ls
e
l
e
n
g
th
(m
s
e
c
)
Pulse Output
00
00
01
Monday
50
Monday at 00:00:01
pulse length approx. 50msec
05
58
--
Wednesday
1010
Wednesday at 05:58
pulse length approx. 1 Minute
(1)
09
--
--
Friday
1010
Friday at 09:00
pulse length approx. 1 hour
(1)
Due to a pulse duration longer than 1000msec (1sec) there is an overlap of the pulse output
(e.g. minute pulse)