Contents
Symbol Definitions
x
Analog Input Module 2MLF-AV8A, AC8A User's Guide
R200
Honeywell
September 2010
4.2
Run parameters setting ................................................................................. 54
Setting items........................................................................................................................ 54
Setting I/O parameters ........................................................................................................ 55
4.3
Special module monitoring .......................................................................... 61
4.4
Register special module variables ............................................................... 65
Registering special module variables .................................................................................. 65
Saving variables .................................................................................................................. 66
Program example with variable and address....................................................................... 66
5.
CONFIGURATION AND FUNCTION OF INTERNAL MEMORY . 69
5.1
Internal memory configuration ..................................................................... 69
Setting area of Run parameters .......................................................................................... 71
5.2
I/O area of A/D converted data ..................................................................... 73
Module Ready/Error (%UXa.b.0, %UXa.b.15; a: Base No., b: Slot No.) ............................ 73
Run channel (%UXa.b.16~23, a: Base No., b: Slot No.) .................................................... 73
Digital output value (%UWa.b.2 ~9, a: Base No., b: Slot No.) ............................................. 73
Detect input signal failure/disconnect flag (%UXa.b.160~167 a: Base No., b: Slot No.) ..... 74
Error clear request flag (%UXa.b.176, a: Base No., b: Slot No.) ......................................... 75
5.3
Operation parameters settings area ............................................................ 76
Address 0 - A/D conversion enable/disable status for each channel ................................... 76
Address 1 - Input voltage/current range .............................................................................. 76
Address 2 - Output data format ........................................................................................... 79
Address 4-11 - Filter constant ............................................................................................. 80
Address 12 - Average process Enable/Disable ................................................................... 81
Address 13 - Average process method (address number 13) ............................................. 82
Address 14-21 - Average value ........................................................................................... 82
Error code (address number 22) ......................................................................................... 83
5.4
Global variable (data area) ............................................................................ 85
How to use global variable .................................................................................................. 85
Local variable registration ................................................................................................... 85
How to use local variables ................................................................................................... 87
5.5
PUT/GET function block use area (parameter area) .................................. 90
PUT instruction .................................................................................................................... 91
GET instruction .................................................................................................................... 93
Example using PUT/GET instruction ................................................................................... 94
Output data range setting .................................................................................................... 97
6.
PROGRAMMING ....................................................................... 107
6.1
Read/Write of operation parameter settings area .................................... 107
Read operation parameters settings area (GET, GETP command) .................................. 107
Содержание 2MLF-AC8A
Страница 14: ...Contents Figures xiv Analog Input Module 2MLF AV8A AC8A User s Guide R200 Honeywell September 2010 ...
Страница 106: ......
Страница 114: ...6 Programming 6 3 Basic program 114 Analog Input Module 2MLF AV8A AC8A User s Guide R200 Honeywell September 2010 ...
Страница 117: ...6 Programming 6 3 Basic program R200 Analog Input Module 2MLF AV8A AC8A User s Guide 117 September 2010 Honeywell ...
Страница 119: ...6 Programming 6 3 Basic program R200 Analog Input Module 2MLF AV8A AC8A User s Guide 119 September 2010 Honeywell ...
Страница 140: ...Honeywell Process Solutions 1860 W Rose Garden Lane Phoenix AZ 85027 USA ...